SUMMARY
The following two sections describe issues and workarounds for using
Bernoulli drives with Windows.
BERNOULLI DRIVES AND WINDOWS 3.1
After the Windows logo screen displays when starting Windows 3.1 in
enhanced mode with a Bernoulli drive present and active, your system may
stop responding (hang). If so, try the following:
- Disable SMARTDRV.EXE in the AUTOEXEC.BAT file to prevent caching the
Bernoulli drive by typing the following line:
C:\WINDOWS\SMARTDRV.EXE D-
where "D" is Bernoulli drive
- Check the Bernoulli driver version. Version 7.02 is the latest version
as of April 22, 1992. Versions 7.00 and higher are compatible with
Windows 3.1. If you have version 4.81 or below, call IOMEGA to obtain
the latest version of the driver. If you use an IBM PS/2 machine with
Micro Channel Architecture (MCA), you need to use version 7.02.
- Check to ensure that a permanent swap file was not created on the
Bernoulli drive. If you find one, remove it and re-create it on a
standard hard drive, or use a temporary swap file on the Bernoulli
drive.
- It may be necessary to insert the following line to the [386ENH] section
of the SYSTEM.INI file to provide greater compatibility with the
Bernoulli drive:
[386ENH]
VIRTUALHDIRQ=OFF
Note: To test if this line is required, start Windows with the
following command line:
If Windows starts successfully, include VIRTUALHDIRQ=OFF.
- Make sure the switches on the Bernoulli adapter card are set correctly.
In addition, the switches on the DEVICE=RCD.SYS line in the CONFIG.SYS
file should be configured correctly for your machine.
Settings on the Bernoulli Adapter Card
Switch number 4 on the card should be set "up" or "on" for compatibility
with 286 or faster machines.
The switch should be set "down" or "off" for compatibility with XT or MCA
machines.
Settings in the CONFIG.SYS
In the CONFIG.SYS file, the RCD.SYS driver is installed for use with the
Bernoulli drive. The RCD.SYS driver works in conjunction with switch number
4 on the adapter card. The appropriate switches for the RCD.SYS line in the
CONFIG.SYS file vary depending on your hardware. The applicable switches
are listed below. For more information on configuring your Bernoulli drive,
please consult your manual, or call Bernoulli.
The RCD.SYS /F option allows access to the Bernoulli drive for fast host
machines (mainly 286 and 386 machines. The RCD.SYS /F0 option allows access
to the drive for 486 machines only. If you are using the /F option, you
must set the controller card switch for Programmed I/O. For more
information, refer to the Bernoulli documentation.
The RCD.SYS /L option locks the Bernoulli drive cartridge, disabling the
Eject button on the drive.
The RCD.SYS /M0 option uses Programmed I/O data transfer and bypasses
Direct Memory Access. This option is used for all MCA machines when
operating in Windows 3.1.
The RCD.SYS /N option disables the connection to any network.
The RCD.SYS /P option notifies the parallel adapter of the Bernoulli drive
to slow down the transfer of data to and from the parallel port(s).
When this problem occurs in Windows 3.1 386 enhanced mode, the physical
hard disk may run continuously until a break is issued. To discover exactly
what is causing the Bernoulli drive to work incorrectly, run RCDDIAG.EXE (a
diagnostic program), and contact IOMEGA technical support.
BERNOULLI DRIVES AND WINDOWS 3.0
When you start Windows 3.0 in enhanced mode on a Bernoulli drive, your
system may stop responding (hang). If so, you may have a conflict between
your RCD.SYS command-line parameters and your Bernoulli card configuration.
RCD.SYS normally uses DMA for I/O. The RCD.SYS /F command-line option
specifies programmed I/O instead of DMA. If you are using RCD.SYS without
the /F option, set your controller card's switch for DMA; if you are using
the /F option, you must set the controller card switch for programmed I/O.
The products included here are manufactured by IOMEGA, a vendor independent
of Microsoft; we make no warranty, implied or otherwise, regarding these
products' performance or reliability.