FIX: The ARM compiler may generate code that causes a Datatype Misalignment exception at run time when you use Platform Builder 4.2 to build Windows CE-based projects for the ARM processor (909973)



The information in this article applies to:

  • Microsoft Windows CE .NET 4.2

SYMPTOMS

When you use Microsoft Platform Builder 4.2 to build Microsoft Windows CE-based projects for the ARM processor, the ARM compiler may generate code that causes a Datatype Misalignment exception at run time. This problem occurs when the following conditions are true:
  • You access memory by using a BYTE pointer.
  • The BYTE pointer value is an odd number.

RESOLUTION

Software update information

A supported software update is now available from Microsoft as Windows CE 4.2 Core OS QFE 909973. To resolve this problem immediately, click the following article number for information about obtaining Windows CE Platform Builder and core operating system software updates:

837392 How to locate core operating system fixes for Microsoft Windows CE Platform Builder products

Prerequisites

This update is supported only if all previously issued updates for this product have also been applied.

Restart requirement

After you apply this update, you must perform a clean build of the whole platform. To clean the platform, click Clean on the Build menu. To build the platform, click Build Platform on the Build menu. You do not have to restart the computer after you apply this update.

Update replacement information

This update does not replace any other updates.

File information

The English version of this software update package has the file attributes (or later file attributes) that are listed in the following table.
File nameFile sizeDateTime
Wincepb42-051116-kb909973-common.msi7,792,12816-Nov-200520:49
The English version of this update has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.
File nameFile sizeDateTimePath
C2_arm.dll884,73631-Oct-200522:00Sdk\Bin\I386

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

MORE INFORMATION

For more information about software update terminology, click the following article number to view the article in the Microsoft Knowledge Base:

824684 Description of the standard terminology that is used to describe Microsoft software updates


Modification Type:MinorLast Reviewed:7/26/2006
Keywords:kbBug kbfix kbQFE kbpubtypekc KB909973 kbAudOEM