Users may not be able to print 3270 print jobs through the SNA Print service in Host Integration Server (905396)
The information in this article applies to:
- Microsoft Host Integration Server 2000
- Microsoft Host Integration Server 2000 SP1
- Microsoft Host Integration Server 2000 SP2
- Microsoft Host Integration Server 2004
SYMPTOMSIn Microsoft Host Integration Server, users may not be able to print 3270 print jobs through the SNA Print service (Snaprint.exe). This problem occurs even though the 3270 print sessions are in an Insession state in SNA Manager. Error messages that are similar to the following are logged in the application event log when this problem occurs:Event ID: 9
Source: SNA Virtual Print Driver
Description:
The GDI routine OpenPrinter has returned an error to the SNA Virtual Print Driver.
Error returned: error code Event ID: 21
Source: SNA Server
Description:
(1124) Negative Response Sent on Connection connection name (SENSE = 814)
SUBCODE INFORMATION
X'1124' A negative response was sent and logged. This error normally follows a more specific error message, depending on the type of negative response sent and its cause. The SNA sense data provides details about the type of error.
Additionally, the affected 3270 printer Logical Units (LU) will have a status of ACTIVE-P(ending) when you view the LUs in Virtual Telecommunications Access Method (VTAM) on the IBM mainframe. CAUSEThe problem occurs when the SNA Print service loses its connection to the physical printer that is defined for a 3270 print session. The connection is lost between the time that a BIND is received for a 3270 print job and the time that actual print data is sent by the mainframe application. The SNA Print service only tries to reconnect to a printer one time for 3270 print sessions when the SNA Print service loses the connection to the physical printer. If the retry attempt fails, the 3270 print session stays in an Insession state. The mainframe application cannot spool print jobs to the print session.RESOLUTIONHost Integration Server 2000A supported hotfix is now available from Microsoft, but it is only intended to correct the problem that is described in this article. Only apply it to systems that are experiencing this specific problem. This hotfix may receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next Host Integration Server 2000 service pack that contains this hotfix. To resolve this problem immediately, contact Microsoft Product Support Services to obtain the hotfix. For a complete list of Microsoft Product Support Services telephone numbers and information about support costs, visit the following Microsoft Web site: Note In special cases, charges that are ordinarily incurred for support calls may be canceled if a Microsoft Support Professional determines that a specific update will resolve your problem. The usual support costs will apply to additional support questions and issues that do not qualify for the specific update in question.
The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.
Date Time Version Size File name
-----------------------------------------------------
08-Aug-2005 22:32 5.0.0.2075 250,128 Ppd3270.dll
08-Aug-2005 22:32 5.0.0.2075 282,896 Winvprt.dll
Note Because of file dependencies, the most recent fix that contains
these files may also contain additional files. Host Integration Server 2004A hotfix is not currently available for Host Integration Server 2004. STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.MORE INFORMATIONAfter you apply the update, the SNA Print service will try to reconnect to the physical printer every 12 seconds until the connection to the printer is successful. An Event ID 9 message that is similar to the one described in the "Symptoms" section will be logged for each retry attempt that fails. The SNA Print service will stop trying if the mainframe application sends a CLEAR request unit (RU) or an UNBIND RU to end the outstanding print job.
Modification Type: | Minor | Last Reviewed: | 7/25/2006 |
---|
Keywords: | kbHotfixServer kbQFE kbhis2000 kbHIS2004 kbfix kbbug kbpubtypekc KB905396 kbAudDeveloper kbAudEndUser |
---|
|