SYMPTOMS
When you use a custom receive pipeline to validate a document structure in Microsoft BizTalk Server 2004, an error message that is similar to the following may be logged in the Event Viewer of the Administration Console:
Event Type: Error
Event Source: BizTalk Server 2004
Event Category: BizTalk Server 2004
Event ID: 5719
Description: There was a failure executing the receive pipeline: "Pipeline.ReceivePipeline" Source: "XML disassembler" Receive Location: "Path\*.xml" Reason: Failed to validate the document: "The SchemaName element is not declared. An error occurred at , (1, 2).".
Note In this error message,
Pipeline is the name of the receive pipeline,
Path is a file path, and
SchemaName is the schema name.
This problem occurs when the following conditions are true:
- The receive pipeline uses the XML Disassembler pipeline component.
- The Document schemas property of the XML Disassembler pipeline component contains XML schemas that do not have unique namespaces.
RESOLUTION
Hotfix information
A supported hotfix is now available from Microsoft, but it is only intended to correct the problem that is described in this article. Only apply it to systems that are experiencing this specific problem. This hotfix may receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next Microsoft BizTalk Server 2004 service pack that contains this hotfix.
To resolve this problem immediately, contact Microsoft Product Support Services to obtain the hotfix. For a complete list of Microsoft Product Support Services telephone numbers and information about support costs, visit the following Microsoft Web site:
Note In special cases, charges that are ordinarily incurred for support calls may be canceled if a Microsoft Support Professional determines that a specific update will resolve your problem. The usual support costs will apply to additional support questions and issues that do not qualify for the specific update in question.
Prerequisites
You must have Microsoft BizTalk Server 2004 Service Pack 1 (SP1) installed to apply this hotfix.
Restart requirement
You do not have to restart the computer after you apply this hotfix.
Hotfix replacement information
This hotfix does not replace any other hotfixes.
File information
The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the
Time Zone tab in the Date and Time tool in Control Panel.
Date Time Version Size File name
----------------------------------------------------------------------
15-Jun-2005 20:15 3.0.6134.0 266,240 Msbts.pipeline.components.dll
Note Because of file dependencies, the most recent hotfix that contains these files may contain additional files.