SYMPTOMS

When you validate an X12 document instance in the BizTalk Editor, you may receive the following error message:
The data contains a field value ("01~26.60~MJ") that doesn't meet maximum length requirement for tag "QTY01" (maximum length is 2).
The value of HL04 is incorrect.
The parser failed to convert the document due to processing errors. See the following messages for details.
Note This may also occur when you process a document instance by using the BizTalk Messaging engine.

CAUSE

Your document instance contains Hierarchical Level (HL) loops that are nested deeper than nine levels.

RESOLUTION

Service Pack Information

To resolve this problem, obtain the latest service pack for Microsoft BizTalk Server 2002. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

815781 How to Obtain the Latest BizTalk Server 2002 Service Pack

Hotfix Information

A supported fix is now available from Microsoft, but it is only intended to correct the problem that is described in this article. Apply it only to computers that are experiencing this specific problem. This fix may receive additional testing. Therefore, if you are not severely affected by this problem, Microsoft recommends that you wait for the next that contains this hotfix.

To resolve this problem immediately, contact Microsoft Product Support Services to obtain the fix. For a complete list of Microsoft Product Support Services phone numbers and information about support costs, visit the following Microsoft Web site:NOTE: In special cases, charges that are ordinarily incurred for support calls may be canceled if a Microsoft Support Professional determines that a specific update will resolve your problem. The typical support costs will apply to additional support questions and issues that do not qualify for the specific update in question.

The English version of this fix has the file attributes (or later) that are listed in the following table. The dates and times for these files are listed in coordinated universal time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.
   Date         Time   Version      Size     File name
   ---------------------------------------------------------
   30-Aug-2002  17:46  3.0.1535.0   712,976  Cisparser.dll    
   30-Aug-2002  17:46  3.0.1535.0   504,080  Validatedoc.dll  

				

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Microsoft BizTalk Server 2002 Service Pack 1.

MORE INFORMATION

For additional information about HL loops and BizTalk Server, click the following article number to view the article in the Microsoft Knowledge Base:

325767 INFO: The Value of HL04 Is Incorrect in BizTalk Server Editor