FIX: Drill-Through Returns Incorrect Data When Dimension Tables Are Aliased in Dimension Editor (293609)



The information in this article applies to:

  • Microsoft SQL Server 2000 Analysis Services

This article was previously published under Q293609
BUG #: 10770 (plato7x)

SYMPTOMS

If your dimension tables are aliased and you select drill-through columns with the same name from multiple tables, you may find the values and columns that are returned by drill-through are incorrect.

NOTE: To alias a dimension table in the Dimension Editor, right-click the title bar of the table and click Change Alias.

RESOLUTION

To resolve this problem, obtain the latest service pack for the Microsoft SQL Server 2000 (the Analysis Services Components - Sql2kasp1.exe). For additional information, click the following article number to view the article in the Microsoft Knowledge Base:

290211 INF: How to Obtain the Latest SQL Server 2000 Service Pack

STATUS

Microsoft has confirmed that this is a problem in SQL Server 2000 Analysis Services version 8.0. This problem was first corrected in the Analysis Services Components of Microsoft SQL Server 2000 Service Pack 1.

Modification Type:MinorLast Reviewed:4/24/2003
Keywords:kbBug kbfix kbssas800sp1fix KB293609 kbAudDeveloper