XCON: Dynamic RAS Connection Hangs Up Before Transferring Mail (272064)
The information in this article applies to:
- Microsoft Exchange Server 5.0
- Microsoft Exchange Server 5.5
This article was previously published under Q272064 SYMPTOMS
When you use a dynamic Remote Access Service (RAS) connection to dial another server, the service hangs up before transferring mail. When you troubleshoot using the RPC Ping command, you receive the following error message:
-RpcServerUseProtSeqEp returned a status 0xE
CAUSE
This issue can occur if the server does not have enough random access memory (RAM) available to accept the connection.
RESOLUTION
To resolve this issue, add more RAM to your server.
Modification Type: | Minor | Last Reviewed: | 4/25/2005 |
---|
Keywords: | kbprb KB272064 |
---|
|