Error Message When You Add LU to Connection and Pool by Using Snacfg.exe (258981)



The information in this article applies to:

  • Microsoft Host Integration Server 2000
  • Microsoft SNA Server 4.0

This article was previously published under Q258981

SYMPTOMS

When you add a logical unit (LU) by using the Snacfg.exe file with a command file that does not end with a carriage return and line feed pair (CR/LF), you may receive the following error message:
There is already an LU with this LU Number.

WORKAROUND

You can work around this problem by ensuring that the command file ends in a carriage return and line feed pair.

MORE INFORMATION

Steps to Reproduce the Problem

  1. Create a file that is named Job4.txt, and use the following 20 lines as the text in the file:

    LUA PALURD03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:2
    LUA PALURD04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:3
    LUA PALURD05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:4
    LUA PALURD06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:5
    LUA PALURE03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:6
    LUA PALURE04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURD03 /LUNUMBER:7
    LUA PALURE05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:8
    LUA PALURE06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:9
    LUA PALURG03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:10
    LUA PALURG04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:11
    LUA PALURG05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:12
    LUA PALURG06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:13
    LUA PALURH03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:14
    LUA PALURH04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:15
    LUA PALURH05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:16
    LUA PALURH06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:17
    LUA PALURI03 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:18
    LUA PALURI04 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:19
    LUA PALURI05 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:20
    LUA PALURI06 /ADD /CONNECTION:APUPOSC1 /POOL:ALURd03 /LUNUMBER:21
    							

    Make sure that the last line does not end with a carriage return and line feed pair.
  2. Create a connection that is named APUPOSC1.
  3. Create an LUA pool that is named ALURD03.
  4. Save your changes in SNA Server Manager.
  5. Type the following at a command prompt:

    snacfg PATH\@job4.txt /v

    Be sure to use the proper path for the command file.
You receive the following error message:
Line no 20: Processing command to add LUA PALURI06
Assigning LU PALURI06 to connection APUPOSC1
There is already an LU with this LU Number.
Command failed

Modification Type:MajorLast Reviewed:3/12/2004