XCON: MTA Stops Processing While Handling Incoming Mail (248732)
The information in this article applies to:
- Microsoft Exchange Server 5.5
- Microsoft Exchange Server 5.5 SP1
- Microsoft Exchange Server 5.5 SP2
- Microsoft Exchange Server 5.5 SP3
This article was previously published under Q248732 SYMPTOMS
Although the EMSMTA process is still apparently running, no work is being done, and no events are logged. If you stop and restart the message transfer agent (MTA), you may receive the following error message:
Windows NT Error 1067
CAUSE
The MTA has received a message from a foreign MTA that contains a trace record with a zero-length Arrival Time attribute. Processing this illegally-formed attribute causes internal context information to be overwritten.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Exchange Server 5.5. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
191014 XGEN: How to Obtain the latest Exchange Server 5.5 Service Pack
WORKAROUND
There is no workaround for this issue. If you create a new MTA database (MTAWIPE), it allows the MTA to start again, but the foreign MTA resends the offending message.
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Exchange Server 5.5 Service Pack 4.MORE INFORMATION
With the application of the hotfix, the MTA rejects the invalid message, logs an event, and sends a non-delivery report (NDR) back with a diagnostic of Invalid Argument.
Modification Type: | Major | Last Reviewed: | 10/2/2003 |
---|
Keywords: | kbbug kbExchange550preSP4fix kbExchange550sp4Fix kbfix kbQFE KB248732 |
---|
|