Memory Leak May Occur If Commerce Server Scriptor Component Is Used in Pipeline (235001)
The information in this article applies to:
- Microsoft Site Server 3.0 Commerce Edition
This article was previously published under Q235001 SYMPTOMS
When the Commerce Server scriptor component is used in a pipeline and the VBScript scripting engine is newer than the version that comes with Internet Explorer 4.01 SP1 (Vbscript.dll version 3.1.0.2230), a memory leak may occur in the Internet Information Server process (Inetinfo.exe). Depending on the load on the Commerce Server store, it may be necessary to restart the Internet Information Server (IIS) computer several times a day.
CAUSE
This problem is caused by the way the Commerce Server scriptor component uses the VBScript scripting engine.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Site Server 3.0. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
219292 How to Obtain the Latest Site Server 3.0 Service Pack
STATUS This problem was first corrected in Site Server 3.0 Service Pack 3.
Modification Type: | Minor | Last Reviewed: | 9/22/2005 |
---|
Keywords: | kbHotfixServer kbQFE kbbug kbfix kbQFE KB235001 |
---|
|