FP2000: VID SDK Query Builder DTC Causes Run-Time Error When Inserted in FrontPage (219147)



The information in this article applies to:

  • Microsoft FrontPage 2000

This article was previously published under Q219147

SYMPTOMS

When you insert the Query Builder Design Time Control (included in the Visual Interdev 6 DTC SDK) in a page in FrontPage, the following run-time error occurs:
Run-time error '-2147467259 (80004005)';

Automation Error

CAUSE

FrontPage does not support the requests the Query Builder design time control makes.

RESOLUTION

To resolve this issue, open the page in Visual Interdev and re-insert the Query Builder design time control. After inserting the design time control, save the page in Visual Interdev.


Modification Type:MajorLast Reviewed:12/2/2000
Keywords:kbbug KB219147