SMS: C++ Runtime Error in SMSMan.exe Using /Q Switch (213312)
The information in this article applies to:
- Microsoft Systems Management Server 2.0
This article was previously published under Q213312 SYMPTOMS
When SMSMan.exe is executed by the Available Programs Manager (APM) using the /Q switch, C++ Runtime Errors may be experienced. If SMSMan.exe /Q is executed by the APM an error dialog box appears on the user's screen.
This dialogue box will contain the following error:
Runtime Error!
Program: \\<ServerName>\<PackageShare>\<PackageID>\SMSMan.exe
abnormal program termination
STATUS
Microsoft has confirmed this to be a problem in Systems Management Server version 2.0.MORE INFORMATION
Executing SMSMAN /Q manually, or outside of APM does not produce this error.
The C++ Runtime Error occurs when /Q is the only switch specified. Using /Q in combination with another switch does not produce the error.
For a complete list of command switches run SMSMAN /?.
Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
---|
Keywords: | kbBug KB213312 |
---|
|