SNA Server Logs Event 3 (1106) Node Configuration Error (195116)
The information in this article applies to:
- Microsoft SNA Server 4.0 SP1
- Microsoft SNA Server 4.0
This article was previously published under Q195116 SYMPTOMS
SNA Server unexpectedly logs the following event in the Windows NT
application event log:
Event ID: 3
Source: SNA Server
Description: (1106) Node Configuration Error
Subcode Information
X'1106' Configuration file is corrupted.
When this occurs, the SNA Server service will end, and an Event ID 624 is
logged, indicating that an SNADump.log has been created.
CAUSE
This problem can occur if an Advanced Program-to-Program Communications
(APPC) or Common Programming Interface for Communications (CPIC)
application attempts to allocate a conversation (by calling [MC_]ALLOCATE
or CMALLC), and specifies an APPC mode name which is not configured in SNA
Server.
RESOLUTION
Microsoft has confirmed this to be a problem in SNA Server versions 4.0 and
4.0 Service Pack 1. This problem was corrected in the latest SNA Server
version 4.0 U.S. Service Pack. For information on obtaining this Service Pack,
query on the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 2/23/2004 |
---|
Keywords: | kbbug kbfix KB195116 |
---|
|