TN3270 Server Rejects Valid BIND with 0821 Sense Code (191625)
The information in this article applies to:
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
- Microsoft SNA Server 3.0 SP2
- Microsoft SNA Server 3.0 SP3
- Microsoft SNA Server 4.0 SP1
- Microsoft SNA Server 4.0
This article was previously published under Q191625 SYMPTOMS
The TN3270 server included with SNA Server may incorrectly reject
a valid
BIND with an IBM Sense Code of 0821. The SNA Server computer logs
the
following event in the Windows NT Application Event Log when this
occurs:
Event ID: 21
Source: SNA Server
Description: (1124) Negative Response Sent on Connection <connection
name> (SENSE = 821).
This was reported by a customer who was using a TN3287 session to
access an
LU1 print session on the mainframe.
CAUSE
The TN3270 server checks incoming BINDs to verify certain BIND
parameters.
One of the validity checks done is to see whether Byte 7 (Common
LU
Protocols) of the BIND is set to x'80'. If this byte is set to any
other
value, the TN3270 server rejects it with IBM Sense Code 0821,
which
indicates invalid session parameters.
In the reported instance of this problem, the LU1 BIND from the
mainframe
had Byte 7 set to x'88', therefore it was being rejected.
RESOLUTIONSNA Server 3.0To resolve this problem, obtain the latest service pack for SNA Server version 3.0. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
184307 How to Obtain the Latest SNA Server Version 3.0 Service Pack
SNA Server 4.0
This problem was corrected in the latest SNA Server version 4.0
U.S.
Service Pack. For information on obtaining this Service Pack,
query on the
following word in the Microsoft Knowledge Base (without the
spaces):
S E R V P A C K WORKAROUND
This problem can be resolved by changing the BIND such that Byte 7
is set to x'80'. Byte 7 of the BIND (Common LU Protocols) is set by the
second byte of the COMPROT parameter of the Log Mode Table (MODEENT)
being used by the LU on the mainframe. A normal COMPROT value for an LU1 (SCS)
printer is x'3080'. In the reported case, COMPROT was set to x'7088' which
resulted in Byte 7 of the BIND being set to x'88'.
STATUSMicrosoft has confirmed that this is a problem in SNA Server versions 3.0,3.0 SP1, 3.0 SP2, 3.0 SP3, 4.0, and 4.0 SP1. This problem was first corrected in SNA Server 3.0 Service Pack 4.
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|
Keywords: | kbbug kbfix KB191625 kbAudDeveloper |
---|
|