PRJ98: User Information Does Not Appear in Splash Screen (191232)
The information in this article applies to:
- Microsoft Project 98 for Windows
This article was previously published under Q191232 SYMPTOMS
When you start Microsoft Project 98, the user name may be displayed in the
splash screen as PLammer Name, the company name may be displayed as
Uninstalled Version, and the serial number may be displayed as No Serial
Number.
NOTE: This information also appears when you click About Microsoft Project on the Help menu.
CAUSECause 1
This problem may occur if you reinstall a Run from Network Server (RNS)
installation of Project 98.
Cause 2
This problem may also occur when the following conditions are true:
- You install Microsoft Project 98 from an administrative installation
point that is located on a network server.
- You run the Setup program, using any of the following /q or /qn
switches to perform a quiet installation:
/q /q0 /q1 /qt /qn1 /qnt
For example, the problem may occur if you run the Setup program using the
following command line:
\\server\share\setup.exe /q1
WORKAROUNDWorkaround for Cause 1
To work around this problem, run Setup and click Remove All before reinstalling Microsoft Project 98.
Workaround for Cause 2
To work around this problem, run Setup and click Remove All. Then, run Setup again without using a /q or /qn switch to reinstall Project.
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article.
Modification Type: | Major | Last Reviewed: | 10/17/2002 |
---|