SNA Server Manager Shows Incorrect DLC t1 Timer Value (189324)
The information in this article applies to:
- Microsoft SNA Server 3.0 SP3
- Microsoft SNA Server 4.0
- Microsoft SNA Server 4.0 SP1
This article was previously published under Q189324 SYMPTOMS
In SNA Server Manager, the 802.2 DLC tab of the DLC Connection Properties
dialog box reports incorrect values for T1 timer ticks.
The drop-down list box reports the following:
Ticks T1 T2 Ti
------------------------------
1 200 ms 40 ms 1 s
2 400 ms 80 ms 2 s
3 600 ms 120 ms 3 s
4 800 ms 160 ms 4 s
5 1 s 200 ms 5 s
6 1 s 400 ms 5 s
7 2 s 800 ms 10 s
8 3 s 1200 ms 15 s
9 4 s 1600 ms 20 s
10 2000 ms 2000 ms 25 s
The drop-down list box should report the following:
Ticks T1 T2 Ti
------------------------------
1 200 ms 40 ms 1 s
2 400 ms 80 ms 2 s
3 600 ms 120 ms 3 s
4 800 ms 160 ms 4 s
5 1 s 200 ms 5 s
6 1 s 400 ms 5 s
7 2 s 800 ms 10 s
8 3 s 1200 ms 15 s
9 4 s 1600 ms 20 s
10 5 s 2000 ms 25 s
(T1 timer 10 should be "5 s" instead of "2000 ms").
CAUSE
This error happens because of a mismatch on the table where timer tick
values are associated with a text string indicating the corresponding
amount of time.
RESOLUTION
Microsoft has confirmed this to be a problem in SNA Server versions 3.0
SP3, 4.0, and 4.0 SP1. We are researching this problem in SNA Server
version 3.0 and will post more information here in the Knowledge Base
as it becomes available.
This problem was corrected in the latest SNA Server version 4.0 U.S.
Service Pack. For information on obtaining this Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
NOTE: A similar problem existed in SNA Server 3.0 and 3.0 SP1. It was
corrected in SNA Server 3.0 SP2.
WORKAROUND
To work around this problem:
- Use the Snacfg.exe command line tool
Modification Type: | Major | Last Reviewed: | 10/23/2003 |
---|
Keywords: | kbbug kbfix KB189324 |
---|
|