NET USE Returns Error 53 When Host Has 3 or more NICs (182825)
The information in this article applies to:
- Microsoft Windows NT Server 4.0 Terminal Server Edition
- Microsoft Windows NT Workstation 4.0
- Microsoft Windows NT Server 4.0
This article was previously published under Q182825 SYMPTOMS
Performing a net use or net view from a host that has 3 or more network
interface cards (NICs) to a destination that is also multihomed can result
in error 53.
CAUSE
NetBT times out when it parses through the list of IP address that it can
use.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Windows NT 4.0 or Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack
STATUSMicrosoft has confirmed that this is a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition Service Pack 4.
Modification Type: | Minor | Last Reviewed: | 9/23/2005 |
---|
Keywords: | kbHotfixServer kbQFE kbbug kbfix kbQFE KB182825 |
---|
|