Application Exception in PPD5250 When Set Line Density Is Zero (182066)
The information in this article applies to:
This article was previously published under Q182066 SYMPTOMS
An application exception occurs in Ppd5250.dll when print data from an
AS/400 contains a Set Line Density (SLD) SCS control code that specifies a
value of zero.
CAUSE
The 5250 print provider tries to determine line density by dividing 72 by
the value specified in the SLD SCS control code. This results in a divide
by zero error and an application exception in Ppd5250.dll if the SLD
control code specifies a value of zero.
STATUS
Microsoft has confirmed this to be a problem in SNA Server version 4.0.
This problem was corrected in the latest SNA Server version 4.0 U.S.
Service Pack. For information on obtaining this Service Pack, query on
the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 9/22/2005 |
---|
Keywords: | kbHotfixServer kbQFE kbbug kbfix KB182066 kbAudDeveloper |
---|
|