After selecting Hardware Setup in NTBACKUP, and pressing the OK button when
the MINIQIC device is shown, the SCSI bus may stop responding. The system
will send a SCSI RESET numerous times before it gives up. If the boot
device happens to be on the same SCSI bus, the system will blue screen with
the following error message:
STOP 0x0000007A KERNEL_DATA_INPAGE_ERROR
This problem seems to occur with every MINIQIC device. This only happens
when a MINIQIC device is attached to a SCSI host adapter controlled by
Aic78xx.sys.
CAUSE
A bit was not getting reset during a PCI Master Abort condition, causing
all SCSIPORT requests to not make it to the SCSI bus.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 4.0.
This problem was corrected in the latest Microsoft Windows NT 4.0 U.S. Service
Pack. For information on obtaining the service pack, query on the following word