Sense Code 080E0000 Trying to Connect to an AS/400 (163517)
The information in this article applies to:
- Microsoft SNA Server 2.0
- Microsoft SNA Server 2.1
- Microsoft SNA Server 2.11
- Microsoft SNA Server 3.0
- Microsoft SNA Server 4.0
This article was previously published under Q163517 SYMPTOMS
Any attempt to connect to an AS/400 fails even when the appropriate device
and controllers exist. The Windows NT Server Event Viewer Application log
records the following event:
Event 18
APPC session activation failure:
BIND negative response or UNBIND request received
Sense data = 080E0000
The AS/400 will show a status on the line and the controller, but will not
show a corresponding device, even if it has been created manually. If the
device has not been created manually, the System Operator message queue on
the AS/400 will record errors related to the creation of the device.
CAUSE
IBM implemented a directory search filter in OS/400 V3R2. This feature, if
not properly configured, will reject connection attempts and will return
the 080E0000 sense code.
Modification Type: | Minor | Last Reviewed: | 3/8/2005 |
---|
Keywords: | KB163517 |
---|
|