SLI Application Stops Responding When Issuing SLI_SEND (163332)
The information in this article applies to:
- Microsoft SNA Server 2.11 SP1
- Microsoft SNA Server 3.0
This article was previously published under Q163332 SYMPTOMS
An LUA SLI application may stop responding when issuing SLI_SEND. This can
occur when the underlying RUI interface returns a primary return code of
PARAMETER_CHECK and secondary return code of REQUIRED_FIELD_MISSING to the
SLI interface.
CAUSE
When an asynchronous RUI_WRITE completes synchronously, the resulting
completion processing is being handled in two places in error.
RESOLUTION
An update to SNA Server 2.11 Service Pack 1 and SNA Server 3.0 corrects
this problem.
The updated modules are:
Windows NT: <snaroot>\System\Winsli32.dll
Windows 95: <winroot>\System\Winsli32.dll
Windows 3.x: <winroot>\System\Winsli.dll
OS/2: <snaroot>\Acssli.dll
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 2.11
Service Pack 1 (SP1) and 3.0. This problem was corrected in the latest Microsoft SNA Server 2.11 and 3.0 U.S. Service Packs. For information on obtaining the service packs, query on the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 11/4/2003 |
---|