IBM Client Access/95 Setup Stops Responding (161773)
The information in this article applies to:
- Microsoft SNA Server 2.11 SP1
This article was previously published under Q161773 SYMPTOMS
When you run IBM Client Access for Windows 95 over the SNA Server 2.11
Service Pack 1 for Windows 95 client software, the Client Access setup
program stops responding when configuring connections to multiple AS/400's
through SNA Server. After pressing CTRL+ALT+DEL, the following appears in
the Close Program dialog box:
AS400 Connections - Primary Environment (Not Responding)
Closing this application succeeds.
When you look at the SNA Server Windows 95 client traces, you see that IBM
Client Access 95 uses the APPC DISPLAY function to dynamically retrieve
configured APPC LU's. The first call to DISPLAY succeeds, although the next
attempt fails with STATE_CHECK. The following DISPLAY call stops and never
returns.
CAUSE
When the application issues the WinAPPCCleanup() call, the SNA Windows 95
client "DMOD" removes all of the routing procedures for the application.
When the application issues the WinAPPCStartup() call again, the DISPLAY
library does not register its routing procedure again, and therefore it can
never receive any more messages.
STATUS
Microsoft has confirmed this to be a problem in the Windows 95 client
included with SNA Server 2.11 Service Pack 1. This problem was corrected in the latest SNA Server version 2.11 U.S. Service Pack. For information on obtaining this service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
A supported fix is now
available, but has not been fully regression-tested and should be applied
only to systems experiencing this specific problem. Unless you are severely
impacted by this specific problem, Microsoft recommends that you wait for
the next Service Pack that contains this fix. Contact Microsoft Technical
Support for more information.
Modification Type: | Major | Last Reviewed: | 6/13/2001 |
---|
Keywords: | kb3rdparty KB161773 |
---|
|