Length = 0 in BIND Causes SNA Server to Reject BIND (160709)
The information in this article applies to:
- Microsoft SNA Server 2.0, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 2.1, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 2.11, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 3.0, when used with:
- the operating system: Microsoft Windows NT
This article was previously published under Q160709 SYMPTOMS
When a host initiated BIND is sent to the SNA Server where the following
two conditions obtain
- there is an incorrect field in the BIND
and
- one of the User Data Structured Subfields' length field is 0,
SNA Server will appropriately reject the BIND's incorrect field with a
0835xxxx sense code, but the last 4 hexadecimal digits will be incorrect.
The 0835xxxx will appear in the event log as:
Event ID 17
APPC session activation failure: BIND negative response sent
Sense data = 0835xxxx
connection = <value>
Session ID = <value>
LFSID = <value>
TH = <value>
RH = <value>
RU = <value>
The last four hexadecimal digits (xxxx) of the sense data correspond to an
offset within the BIND command that points to the parameter that was not
recognized or supported by the BIND receiver, in this case SNA Server.
CAUSE
The SNA Server service gets confused because of the 0 length field. It
therefore reports an incorrect offset in the 0835 sense code.
RESOLUTION
There is no current workaround. When using the 0835 sense code in
diagnosis, be aware that if there are User Data Subfields whose length
field is 0, the offset value may point to a perfectly legitimate subfield.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 2.0,
2.1, 2.11, 2.11 SP1, and 3.0. We are researching this problem and will post
new information here in the Microsoft Knowledge Base as it becomes
available.
Modification Type: | Major | Last Reviewed: | 11/26/2003 |
---|
Keywords: | kbbug kbnetwork KB160709 |
---|
|