"STOP: 0x00000093" with Security Dongle Adapter (157912)
The information in this article applies to:
- Microsoft Windows NT Server 4.0
- Microsoft Windows NT Workstation 4.0
This article was previously published under Q157912 SYMPTOMS
When you start your computer, you may receive the following error message:
STOP: 0x00000093
INVALID_KERNEL_HANDLE
CAUSE
This error message can be caused by the driver for a dongle security
device. Two such drivers known to cause this error message are:
RESOLUTION
If you receive this error after installing software in your Windows NT
4.0 installation, you may be able to resolve this issue by starting the
computer using the Last Known Good configuration. However, if the error
occurred after upgrading to Windows NT 4.0 you may resolve the issue, by
renaming the driver using the steps in the appropriate section below.
Windows NT Installed on a FAT Partition- Start your computer using the MS-DOS option from the NT OS Loader.
(If MS-DOS is not an option, boot your computer using an MS-DOS
boot disk.)
- Rename the driver.
- Restart your computer and start Windows NT.
Windows NT Installed on an NTFS Partition- Install Windows NT in an alternate folder on your computer.
- Log in to the new installation of Windows NT and run Command Prompt.
- Rename the driver.
- Restart your computer using the original installation of Windows NT.
NOTE: Some of your software may require these drivers to be present in
order to operate properly and may generate error messages when you restart
Windows NT 4.0.
MORE INFORMATION
For updated versions of these drivers, contact the manufacturer of the
driver.
Modification Type: | Major | Last Reviewed: | 8/9/2001 |
---|