APPC DISPLAY Verb May Return Incorrect LU6.2 Session Info (151698)
The information in this article applies to:
- Microsoft SNA Server 2.0
- Microsoft SNA Server 2.1
- Microsoft SNA Server 2.11
This article was previously published under Q151698 SYMPTOMS
When an Advanced Program-to-Program Communications (APPC) application calls
the DISPLAY function and requests information on active LU6.2 sessions
(using the sess_info structure), SNA Server may return incorrect
Request/Response Unit (RU) sizes or pacing window sizes.
CAUSE
The SNA Server APPC DISPLAY function implements sess_info formatting
incorrectly in some cases, namely, where the LU-SSCP session properties
are returned with the mode name from the PLU-SLU session. This could cause
the APPC application to retrieve RU sizes or pacing window sizes that do
not match the actual values negotiated on the PLU-SLU BIND.
STATUS
Microsoft has confirmed this to be a problem in SNA Server 2.11 and 2.11
Service Pack 1.
This problem was corrected in the latest Microsoft SNA Server 2.11 U.S.
Service Pack. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 8/11/2005 |
---|
Keywords: | KB151698 |
---|
|