Connectoid's Associated Script File Does Not Run (140684)
The information in this article applies to:
- Microsoft Windows 95
- Microsoft Plus! for Windows 95
This article was previously published under Q140684 SYMPTOMS
When you associate a script file with a Dial-Up Networking connectoid
using the Dial-Up Scripting Tool included with Microsoft Plus!, the script
file may not run when you double-click the connectoid.
CAUSE
This behavior can occur if the Dial-Up Networking connectoid that the
script file is associated with is configured to open a terminal window
after dialing. When a connectoid is configured to open a terminal window
after dialing, an associated script file does not run.
RESOLUTION
Configure the connectoid so that a terminal window is not opened after
dialing. To do so, follow these steps:
- Use the right mouse button to click the connectoid, and then click
Properties on the menu that appears.
- Click Configure, and then click the Options tab.
- Click the "Bring up terminal window after dialing" check box to
clear it, and then click OK.
Modification Type: | Major | Last Reviewed: | 7/28/2001 |
---|
Keywords: | kbDialUp KB140684 |
---|
|