Issues with Multiple Concentrators with Digi DIGIFEP5.SYS Driver (140264)



The information in this article applies to:

  • Microsoft Windows NT Workstation 3.5
  • Microsoft Windows NT Workstation 3.51
  • Microsoft Windows NT Server 3.5
  • Microsoft Windows NT Server 3.51

This article was previously published under Q140264

SYMPTOMS

On Windows NT Remote Access Service (RAS) servers with multiple Digiboard multi-serial adapters attached to 30 or more ports, you may encounter problems with ports not resetting, users being disconnected, and "Line Non-Operational" errors when you view the ports in RASADMIN. Additionally, the RAS connection is intermittently slow .

This problem can be seen on models that utilize the DIGIFEP5.SYS driver.

The ports that are affected do not reactivate until you stop the RAS service and the Digifep5 driver.

NOTE: To stop the services from the command line, type:

NET STOP REMOTEACCESS

NET STOP DIGIFEP5



STATUS

Microsoft has confirmed this to be a problem in Windows NT version 3.51. A fix to this problem is in development, but has not been regression-tested and may be destabilizing in production environments. Microsoft does not recommend implementing this fix at this time. Contact Microsoft Product Support Services for more information on the availability of this fix.


Modification Type:MajorLast Reviewed:12/16/2003
Keywords:kbHardware KB140264