CPI-C cmecsu() Call Always Returns pLengthUserID=1 (140037)



The information in this article applies to:

  • Microsoft SNA Server 2.0, when used with:
    • the operating system: Microsoft Windows NT
  • Microsoft SNA Server 2.1, when used with:
    • the operating system: Microsoft Windows NT
  • Microsoft SNA Server 2.11, when used with:
    • the operating system: Microsoft Windows NT

This article was previously published under Q140037

SYMPTOMS

If a CPI-C application calls the following APIs:

cmscsu() Set_Conversation_Security_User_ID
cmecsu() Extract_Conversation_Security_User_ID

the returned length on the extract call is always set to 1. It should return the value that was passed through:

cmscsu(pConversationID, pUserID, pLengthUserID)

RESOLUTION

Microsoft has updated the following files to correct this problem:
   Client Platforms       Updated Files
   -----------------------------------------------------------

   Windows NT clients     <SNAroot>\system\WCPIC32.DLL
   Windows 95 clients     <WIN95root>\system\WCPIC32.DLL
   Windows 3.x clients    <WIN3Xroot>\system\WINCPIC.DLL
   OS/2 clients           <SNAroot>\system\CPIC.DLL
				

STATUS

Microsoft has confirmed this to be a problem in SNA Server for Windows NT. This problem was corrected in the latest SNA Server for Windows NT, 2.11 U.S. Service Pack. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


Modification Type:MajorLast Reviewed:12/5/2003
Keywords:kbbug kbfix KB140037