FPNW: The Bindery Library Could Not Access the PDC for Write (128532)
The information in this article applies to:
- Microsoft Windows NT Server 3.51
- Microsoft File and Print Services for NetWare 3.51
This article was previously published under Q128532 SYMPTOMS
After you promote different backup domain controllers (BDCs) to the role of
primary domain controller (PDC) several times, the File and Print Services
for NetWare (FPNW) server is not able to access the PDC and one or more of
the following symptoms occur:
NOTE: JetDirect is no longer supported by HP.
SDI (Simple Device Installation) is now used to install
network printers. For more information on this,
see: CAUSE
FPNW does not attempt to get the new PDC location. It fails the call and
postpones obtaining a new PDC location until the next call. Consequently,
the write handle on the PDC is lost.
WORKAROUND
To work around this problem, stop and restart FPNW service in Control Panel
Services.
STATUS
Microsoft has confirmed this to be a problem in File and Print Services for
A supported fix is now available, but is not fully regression-tested and
should be applied only to systems experiencing this specific problem.
Unless you are severely impacted by this specific problem, Microsoft
recommends that you wait for the service pack release containing this fix.
Contact Microsoft Product Support Services for more information.
Microsoft does not recommend implementing this fix at this time. Contact
Microsoft Product Support Services for more information on the availability
of this fix.
Modification Type: | Major | Last Reviewed: | 7/13/2006 |
---|
Keywords: | kbnetwork KB128532 |
---|
|