Err Msg Installing IntelliType: Unable to show Program... (126129)
The information in this article applies to:
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Workstation 3.5
- Microsoft Windows NT Server 3.1
- Microsoft Windows NT Server 3.5
- Microsoft Natural Keyboard with IntelliType software
This article was previously published under Q126129 SYMPTOMS
When you install IntelliType software under Windows NT version 3.1 or 3.5,
the following error appears:
Unable to show Program Manager group: 'Microsoft Input Devices'
When you choose OK, the following message appears:
Setup failed! Contact Microsoft Produce Support Services for help.
CAUSE
This problem occurs when you have 40 common Program Manager groups, and the
IntelliType software attempts to add one more common group. Windows NT
Program Manager does not support more than 40 common groups and 40 personal
groups.
WORKAROUND
To work around this problem:
- Delete one or more of the existing common groups and re-install the
IntelliType software.
-or-
- Delete one or more of common groups and manually create a Common Group
called Microsoft Input Devices. Manually create a program item for
\MSINPUT\KEYBOARD\KBDX32.EXE. Manually create another program item for
%SYSTEMROOT%\TASKSW32.EXE.
-or-
- Manually create programs items for \MSINPUT\KEYBOARD\KBDX32.EXE and
%SYSTEMROOT%\TASKSW32.EXE in an existing program group.
STATUS
Microsoft has confirmed this to be a problem in IntelliType version 1.0. We
are researching this problem and will post new information here in the
Microsoft Knowledge Base as it becomes available.
Modification Type: | Minor | Last Reviewed: | 8/16/2005 |
---|
Keywords: | KB126129 |
---|
|