SYMPTOMS
When you are viewing a table in Design view, and you choose the Undo
Property Setting command, you may receive a general protection (GP) fault
in MSACCESS.EXE.
CAUSE
This problem occurs if you change the FieldSize property setting of a
Number field from Double to another size, and then choose Undo Property
Setting from the Edit menu.
RESOLUTION
Instead of choosing Undo Property Setting to restore the field's FieldSize
property setting, select the setting you want from the list of available
settings.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Access version
2.0. This problem no longer occurs in Microsoft Access version 7.0.
REFERENCES
For more information about the FieldSize property, search for "FieldSize,"
and then "FieldSize Property" using the Microsoft Access Help menu.