FIX: Nesting OLE Automation Calls Causes GP Fault (114000)
The information in this article applies to:
- Microsoft Visual Basic Standard Edition for Windows 3.0
- Microsoft Visual Basic Professional Edition for Windows 3.0
This article was previously published under Q114000 SYMPTOMS
Nesting multiple OLE Automation property accesses and/or method invocations
within the same procedure may lead to temporary memory loss or a general
protection (GP) fault.
CAUSE
When Visual Basic makes the cross process calls to perform the property
access or method invocation it does not release the temporary space
allocated until the procedure completes execution.
STATUS
Microsoft has confirmed this to be a bug in the Microsoft products listed
at the beginning of this article. This problem has been corrected in Visual
Basic version 4.0.
Modification Type: | Major | Last Reviewed: | 10/29/2003 |
---|