Inaccessible Boot Device STOP Message with Micronics 486DX/66 (108417)
The information in this article applies to:
- Microsoft Windows NT Server 3.1
- Microsoft Windows NT Workstation 3.1
This article was previously published under Q108417 SYMPTOMS
Windows NT does not install properly on Micronics 486DX/66 computers with
Ultrastor 34F.
When you start Windows NT on a Micronics 486DX/66 computer, the NTLOADER
starts, the screen clears to blue, NTLOADER queries the hard disk and then
you receive the following STOP message:
0x0000007B Inaccessible Boot Device.
CAUSE
This problem is related to the combination of Ultrastor 34F disk
controller and the Micronics board (09-00183-06 486DX/66).
WORKAROUND
To work around this problem, do the following.
- Make sure the Micronics computer has the latest Phoenix BIOS (0.01 JX30-
06, Rev. B3).
- Replace the Ultrastor 34F with a Bustec BT-445S.
Other workarounds using different hardware may also work.
The products included here are manufactured by vendors independent of
Microsoft; we make no warranty, implied or otherwise, regarding these
products' performance or reliability.
Modification Type: | Major | Last Reviewed: | 10/30/2003 |
---|