Patch Name: PHSS_30526 Patch Description: s700_800 11.00 OV ITO6.0X Intermediate server A.06.17 Creation Date: 04/03/19 Post Date: 04/03/22 Hardware Platforms - OS Releases: s700: 11.00 s800: 11.00 Products: OpenView IT/Operations 6.0 Filesets: OVOPC.OVOPC-UX-MGR78,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP OVOPC.OVOPC-GUI-ENG,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP OVOPC.OVOPC-LIB,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP OVOPC-OVW.OVOPC-OVW-MGR,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP OVOPC.OVOPC-GUI,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP OVOPC-ORA.OVOPC-UX-ORAA,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP OVOPC-JPN.OVOPC-GUI-JPN,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP OVOPC-ORA.OVOPC-GUI-ORA,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP OVOPC-ORA.OVOPC-UX-ORAB,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP Automatic Reboot?: No Status: General Release Critical: Yes PHSS_30526: ABORT PHSS_29228: ABORT Category Tags: defect_repair general_release critical halts_system Path Name: /hp-ux_patches/s700_800/11.X/PHSS_30526 Symptoms: PHSS_30526: Change Request: 8606346000 Customer is getting the following error message when an owned message was acknowledged by a finished operator initiated action: opcuiwww (ITO WWW UI server)(24517) [escal.scp:618]: No according data found in the database. (OpC50-3) WARNING opcuiwww (ITO WWW UI server)(24517) [OvCorUiCommLinkServ.cpp:712]: Execution of API call failed. Error code: No error message for error 1 defined. (ITO210-131) Change Request: B555029712 The opcmsgrd discards messages from Novell agents as being corrupt. Change Request: 8606349913 opctranm can be used from remote system. PHSS_29228: Change Request: 8606315349 In the Motif GUI, the regrouping conditions can be configured in a certain order since the order matters when a message is being processed. However, when an opccfgdwn is run with regrouping conditions checked followed by opccfgupld, the order is not preserved. Change Request: H555010738 The opcmsgm process may crash during startup or when messages are acknowledged. Change Request: B555023738 opcctrlovw aborts when exiting. It still performs the desired functionality before aborting. Change Request: B555016453 The remote installation of a windows agent using an Installation Server fails in the inst.sh script: /opt/OV/bin/OpC/agtinstall/opcwntping[457]: OPC_UNKNOWN_PASSWORD: The specified number is not valid for this command. Change Request: B555020689 opccfgupld detects OpC50-82 if NEW_MESSAGE_GROUP isn't specified in the regroup condition Change Request: B555017415 The agent software distributions fails if the target nodes root password contains double quotes. You get the error message "ERROR: Problems transferring package ... to system ... via ftp service. Check the service manually" Change Request: B555016454 When installing an NT agent: 1. inst.sh asks for the administrative user name, but skips asking for a password. 2. the retry loop for entering login information does not work (it does not work for manual inst.sh nor for GUI- based installation) Change Request: B555013220 An escalated message is only acknowledged on the escalation manager and not on the source manager, if the message is acknowledged using opcack, opcackmsg or opcackmsgs. Change Request: 8606293846 The downloaded history files contain the message times in seconds since epoch (1 Jan 1970) and there is no command line utility to convert these times into readable format. Change Request: 8606301535 checkuiwww fails to show the operator's name when run on HP-UX 11.11 Change Request: H555010708, H555010685 The opcnode_get_list() API used in the opcnode utility to get a list of all the nodes has problems in handling database errors so that an 'opcnode -list' call can abort. Change Request: B555018218 If message forwarding is setup between a Japanese VPOW Server and a Japanese OVOU Server and the agent's character set on the VPOW server is utf8 instead of sjis, opcmsgm on OVOU crashes. Change Request: 8606330995 If MoM is used to forward messages between two servers, and opcdbinst -hist is used to remove history messages from one server, then messages are left in the opc_forward_msgs table. Change Request: B555018347 The local_agt_creation_time field in the database has wrong values. This field is used for reports and shows the date and time in agent timezone when the message was created. Change Request: 8606318934 Typo in message: MESSAGE OpC30-154: The NT Event Log '...' could not be read, because it is corrupt. Please clean the corrupted NT Event Log so that further monitoring is possible. Suppressing further error messages. Change Request: B555016295 If a Windows (NT/2000) as the Administrator password with a '$' character, e.g. test$test, then the standard installation will fail in step II. Change Request: B555023763 The opcmsgrd process could abort if it gets a corrupted message. Change Request: B555018082 opccfgupld aborts with ORA-02291 when uploading a node hierarchy that contains a node that is not in the node bank but in the opc_node_names database table (for example because there are messages for this node). Change Request: B553009432 When adding a new node, the "Communications Options..." window is corrupt until you have entered a hostname or label. Change Request: R555025070 Agent software distribution does not use an alternate user account consistently: The installation tries to copy some files to the node using the default root account instead. Change Request: 8606306731 The current instruction text for OpC30-101 is only related to the Logfile Encapsulator, but the error can happen in other subagents as well. Change Request: 8606329163 In a primary and secondary MoM configuration, forwarded messages on the secondary are acknowledged by "OpC" even if they have been acknowledged by a different operator on the primary. Change Request: B555016510 Notification service information in the message details window does not get set after automatic or manual unbuffering of a message in the pending browser although the notification service is called correctly. Change Request: 8606176793 The MotifGUI cannot be started if the opcsvinfo config file is not readable by the user which wants to log in. You get this error message in the opcerror file: 01/05/01 13:23:49 ERROR opcuiop(23342) [ostart.c:961]: opc_connect() call failed. Cannot start Motif Operator GUI. Please try again later. (OpC60-45) 01/05/01 13:23:49 ERROR opcuiop(23342) [error.c:165]: Error during login occurred. (OpC60-15) Change Request: 8606297838 When a node gets deleted in VPO which doesn't exist in NNM's topology database (because the node was never discovered by NNM or the node was automatically deleted by netmon because it was down for a long period of time), the "Node Bank" delete operation doesn't remove the OPC associated fields in NNM's object database, thus preventing the object from being removed by normal procedures. Change Request: B555024355 opcdbmsgmv locks all messages that are marked, although only 100 are processed at a time and then committed. Change Request: B555022719 During unbuffering of buffered messages OVO calls the notification service that was active when the message was received rather than the current one Change Request: 8606317566 Template autoactions do not work after the first message when: - autoaction execution location is on the OvO server, - autoaction template is managed node other than OvO server - suppress count duplicate messages is set on server. Change Request: B555018620, 8606334089 Erros occur when trying to add more than 50 licenses. Change Request: 8606299686 The template condition is configured to start an automatic action on the message sending node. The output of the action can later be found in the message's annotations. The timestamps in these annotations are misleading. If the OVO server is down during the time the message is created, because of the action started locally on the message sending node the action will immediately be executed but only later be delivered to the OVO server when the the server is up again. However, the timestamps of the starting and finish point of the action will be set to/later than the 'received time' on the server and not to the actual time when the action was executed. This might lead to misinterpretation of the action output! Change Request: 8606315672 opcmomchk indicates syntax of outage template is "ok" when there is actually an error in the file. Error condition: If an outage template is referencing a condition status variable (CONDSTATUSVAR), but the variable is not defined. Change Request: B555018434 opchistdwn unnecessarily searches for nodes with a NULL ID. Change Request: B555027173 opccfgtest core dumps with a Bus Error Change Request: B555017826 opcdbpwd allows the user to set a password that is too long. OVO is no longer able to connect to the database. It is not even possible any more to change the password again because opcdbpwd can't connect either. Change Request: 8606167671, 8606265787, 8606257680, 8606267066 The nodes in the Motif operator GUI are not sorted in lexicographical order. Change Request: B555023302 opcragt fails with OpC10-1/OpC40-604/OpC140-100 if the nodegroup contains more than 80 nodes. Change Request: 8606323697 The opcactm performance suffers if you have lots of auto- action responses buffered. The related messages in the message browser have the incorrect status flag and do not have the correct annotations as the action-response is being buffered in the opcactm. The trouble ticket script, when activated, is called when the message is received and is therefore missing the annotations because the action response is still being buffered in opcactm. Defect Description: PHSS_30526: Change Request: 8606346000 There was a timing problem when the Java GUI was getting the Own information and the message was just acknowledged at that time. Now, the not found error will be mapped to not owned. Change Request: B555029712 The opcmsgrd message plausibility check claims that messages from Novell agents are corrupt because one of their internal attributes has unusual values. Change Request: 8606349913 ovoareqdlr verifies that the request has been sent from the local machine. If ITA is installed, set OPC_ITA_INSTALLED TRUE in opcsvinfo and please contact HP support. PHSS_29228: Change Request: 8606315349 In the Motif GUI, the regrouping conditions can be configured in a certain order since the order matters when a message is being processed. However, when an opccfgdwn is run with regrouping conditions checked followed by opccfgupld, the order is not preserved. Change Request: H555010738 The opcmsgm process may crash during startup or when messages are acknowledged. The crash occurs because an uninitialized variable is passed to the realloc() function. The affected variable is now initialized to NULL. Change Request: B555023738 opcctrlovw aborts when exiting. It still performs the desired functionality before aborting. Change Request: B555016453 The remote installation of a windows agent using an Installation Server fails in the inst.sh script: /opt/OV/bin/OpC/agtinstall/opcwntping[457]: OPC_UNKNOWN_PASSWORD: The specified number is not valid for this command. Change Request: B555020689 opccfgupld detects OpC50-82 if NEW_MESSAGE_GROUP isn't specified in the regroup condition Change Request: B555017415 The root password is not quoted before passing it to the ftp program which should transfer the agent package and installation scripts to the target node. So the ftp service does not recognize the password string. Change Request: B555016454 When installing an NT agent: 1. inst.sh asks for the administrative user name, but skips asking for a password. 2. the retry loop for entering login information does not work (it does not work for manual inst.sh nor for GUI- based installation) Change Request: B555013220 An escalated message is only acknowledged on the escalation manager and not on the source manager, if the message is acknowledged using opcack, opcackmsg or opcackmsgs. Change Request: 8606293846 Added a /opt/OV/contrib/OpC/strftime utility which converts given times into readable format. Change Request: 8606301535 checkuiwww fails to show the operator's name when run on HP-UX 11.11 Change Request: H555010708, H555010685 opcnode_get_list() API is used in opcnode to get a list of all the nodes. If a database error occurs, an internal variable is left uninitialized which might lead to a crash when freeing memory for it. A check has been added to ensure the variable has been initialized before freeing memory for it. In addition to that, the query used to get information about external nodes is now more robust. Change Request: B555018218 If message forwarding is setup between a Japanese VPOW Server and a Japanese OVOU Server and the agent's character set on the VPOW server is utf8 instead of sjis, opcmsgm on OVOU crashes. Change Request: 8606330995 If only -act or -hist is used with opcdbinst, opc_forward_msgs is not trimmed. Now, messages that will no longer have a corresponding message in opc_act_messages or opc_hist_messages will also be removed when opcdbinst -act or -hist is called. Change Request: B555018347 The local_agt_creation_time field in the database has wrong values. This field is used for reports and shows the date and time in agent timezone when the message was created. Change Request: 8606318934 Fixed in the A.07.12 Windows agent patches. Change Request: B555016295 If a Windows (NT/2000) as the Administrator password with a '$' character, e.g. test$test, then the standard installation will fail in step II. Change Request: B555023763 The opcmsgrd process aborts if it gets a corrupted message. The flexible attributes of the message are not included in the plausibility check so that opcmsgrd would instead allocate large memory chunks and abort after reaching maxdsize. Change Request: B555018082 opccfgupld aborts with ORA-02291 when uploading a node hierarchy that contains a node that is not in the node bank but in the opc_node_names database table (for example because there are messages for this node). Change Request: B553009432 There were no defaults set for the "communication options" window. Defaults are now set. Change Request: R555025070 Agent software distribution does not use an alternate user account consistently: The installation tries to copy some files to the node using the default root account instead. Change Request: 8606306731 The current instruction text for OpC30-101 is only related to the Logfile Encapsulator, but the error can happen in other subagents as well. Change Request: 8606329163 On a MOM target server, OpC is always sent as the acknowledging operator of a forwarded message. When OPC_MON_SEND_OP_ACK is set in opcsvinfo, the actual acknowledging operator will be sent instead of OpC. This patch or higher is required on both the target and source servers in order for this variable to take affect. This variable only needs to be set on the target servers that will send their operator id with the acknowledgment. Change Request: B555016510 Notification service information in the message details window does not get set after automatic or manual unbuffering of a message in the pending browser although the notification service is called correctly. Change Request: 8606176793 The MotifGUI cannot be started if the opcsvinfo config file is not readable by the user which wants to log in. You get this error message in the opcerror file: 01/05/01 13:23:49 ERROR opcuiop(23342) [ostart.c:961]: opc_connect() call failed. Cannot start Motif Operator GUI. Please try again later. (OpC60-45) 01/05/01 13:23:49 ERROR opcuiop(23342) [error.c:165]: Error during login occurred. (OpC60-15) Change Request: 8606297838 When a node gets deleted in VPO which doesn't exist in NNM's topology database (because the node was never discovered by NNM or the node was automatically deleted by netmon because it was down for a long period of time), the "Node Bank" delete operation doesn't remove the OPC associated fields in NNM's object database, thus preventing the object from being removed by normal procedures. Change Request: B555024355 opcdbmsgmv locks all messages that are marked, although only 100 are processed at a time and then committed. Change Request: B555022719 During unbuffering of buffered messages OVO calls the notification service that was active when the message was received rather than the current one. If OPC_NOTIF_WHEN_UNBUFFER is set to TRUE then notification services are assigned when the message is unbuffered. Change Request: 8606317566 Auto actions will be executed if duplicate count is set if OPC_EXEC_AA_WITH_DUPL_SUPPR is set to TRUE Change Request: B555018620, 8606334089 Erros occur when trying to add more than 50 licenses. Change Request: 8606299686 The template condition is configured to start an automatic action on the message sending node. The output of the action can later be found in the message's annotations. The timestamps in these annotations are misleading. If the OVO server is down during the time the message is created, because of the action started locally on the message sending node the action will immediately be executed but only later be delivered to the OVO server when the the server is up again. However, the timestamps of the starting and finish point of the action will be set to/later than the 'received time' on the server and not to the actual time when the action was executed. This might lead to misinterpretation of the action output! Change Request: 8606315672 opcmomchk indicates syntax of outage template is "ok" when there is actually an error in the file. Error condition: If an outage template is referencing a condition status variable (CONDSTATUSVAR), but the variable is not defined. Change Request: B555018434 opchistdwn unnecessarily searches for nodes with a NULL ID. Change Request: B555027173 opccfgtest core dumps with a Bus Error Change Request: B555017826 opcdbpwd allows the user to set a password that is too long. OVO is no longer able to connect to the database. It is not even possible any more to change the password again because opcdbpwd can't connect either. Change Request: 8606167671, 8606265787, 8606257680, 8606267066 OVO will now create the managed nodes in sorted order when logging in the first time. To re-sort the nodes in the managed nodes submap of an operator, you need to drop the OVW map: ovw -deleteMap When the operator now logs in again, the managed nodes submap will be re-created ordered. Note, that this re-creation of the map will take some time. It is therefore recommended to only re-create the map from time to time or after major changes. Change Request: B555023302 DCE security was being initialized each time a command was being executed on a node. This caused the whole nodebank to be loaded each time as well. Now it is only initialized once. Change Request: 8606323697 Its now possible to configure the buffering of running actions with two new opcsvinfo config variables: OPC_TT_MAX_RESP_AGE defining the max age of an action in the opcactm buffer. And OPC_TT_ACT_BUFFER_CHECK defining how often opcactm checks the action buffer Enhancement: No SR: R555025070 H555010738 H555010708 H555010685 B555029712 B555027173 B555024355 B555023763 B555023738 B555023302 B555022719 B555020689 B555018620 B555018434 B555018347 B555018218 B555018082 B555017826 B555017415 B555016510 B555016454 B555016453 B555016295 B555013220 B553009432 8606349913 8606346000 8606334089 8606330995 8606329163 8606323697 8606318934 8606317566 8606315672 8606315349 8606306731 8606301535 8606299686 8606297838 8606293846 8606267066 8606265787 8606257680 8606176793 8606167671 Patch Files: OVOPC.OVOPC-UX-MGR78,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: /opt/OV/bin/OpC/install/opclic /opt/OV/bin/OpC/opcuiadm.bin /opt/OV/bin/OpC/agtinstall/opcprocs /opt/OV/contrib/OpC/checkuiwww /opt/OV/bin/OpC/install/opctranm /opt/OV/bin/OpC/agtinstall/opcwntprocs /opt/OV/contrib/OpC/strftime /opt/OV/contrib/OpC/opcqschk /opt/OV/bin/OpC/agtinstall/inst.sh /opt/OV/bin/OpC/ovoareqhdlr OVOPC.OVOPC-GUI-ENG,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: /opt/OV/lib/nls/C/opcinstr.cat /opt/OV/lib/nls/C/opcsv.cat OVOPC.OVOPC-LIB,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: /opt/OV/lib/libopcsv_r.sl /opt/OV/lib/libopcassvn.sl OVOPC-OVW.OVOPC-OVW-MGR,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/bin/opcctrlovw /opt/OV/lib/libopcctrlovw.sl OVOPC.OVOPC-GUI,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: /opt/OV/lib/libopcui.sl OVOPC-ORA.OVOPC-UX-ORAA,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/bin/OpC/opcdispm /opt/OV/bin/OpC/opcackmsg /opt/OV/bin/OpC/opcragt /opt/OV/bin/OpC/opcmsgm /opt/OV/bin/OpC/opcackmsgs /opt/OV/bin/OpC/opcactm /opt/OV/bin/OpC/opcctlm /opt/OV/bin/OpC/opcmsgrd /opt/OV/contrib/OpC/opccfgtest OVOPC-JPN.OVOPC-GUI-JPN,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/lib/nls/ja_JP.SJIS/opcsv.cat /opt/OV/lib/nls/ja_JP.SJIS/opcinstr.cat OVOPC-ORA.OVOPC-GUI-ORA,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/lib/libopcdb.sl /opt/OV/bin/OpC/opcuiop OVOPC-ORA.OVOPC-UX-ORAB,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/bin/OpC/opcuiopadm /opt/OV/bin/OpC/opccfgupld /opt/OV/bin/OpC/opcuiadm /opt/OV/bin/OpC/opcdbinst /opt/OV/bin/OpC/opcack what(1) Output: OVOPC.OVOPC-UX-MGR78,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: /opt/OV/bin/OpC/install/opclic: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcuiadm.bin: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/agtinstall/opcprocs: None /opt/OV/contrib/OpC/checkuiwww: HP OpenView VantagePoint A.06.09 (10/12/01) /opt/OV/bin/OpC/install/opctranm: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/agtinstall/opcwntprocs: None /opt/OV/contrib/OpC/strftime: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/contrib/OpC/opcqschk: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/agtinstall/inst.sh: HP OpenView VantagePoint A.06.17 (03/09/04) /opt/OV/bin/OpC/ovoareqhdlr: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) OVOPC.OVOPC-GUI-ENG,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: /opt/OV/lib/nls/C/opcinstr.cat: None /opt/OV/lib/nls/C/opcsv.cat: None OVOPC.OVOPC-LIB,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: /opt/OV/lib/libopcsv_r.sl: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/lib/libopcassvn.sl: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) OVOPC-OVW.OVOPC-OVW-MGR,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/bin/opcctrlovw: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/lib/libopcctrlovw.sl: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) OVOPC.OVOPC-GUI,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: /opt/OV/lib/libopcui.sl: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) OVOPC-ORA.OVOPC-UX-ORAA,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/bin/OpC/opcdispm: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcackmsg: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcragt: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcmsgm: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcackmsgs: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcactm: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcctlm: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcmsgrd: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/contrib/OpC/opccfgtest: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) OVOPC-JPN.OVOPC-GUI-JPN,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/lib/nls/ja_JP.SJIS/opcsv.cat: None /opt/OV/lib/nls/ja_JP.SJIS/opcinstr.cat: None OVOPC-ORA.OVOPC-GUI-ORA,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/lib/libopcdb.sl: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcuiop: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) OVOPC-ORA.OVOPC-UX-ORAB,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: /opt/OV/bin/OpC/opcuiopadm: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opccfgupld: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcuiadm: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcdbinst: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) /opt/OV/bin/OpC/opcack: HP OpenView VantagePoint A.06.17 PHSS_30526 (03/09/0 4) cksum(1) Output: OVOPC.OVOPC-UX-MGR78,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: 2263425440 164872 /opt/OV/bin/OpC/install/opclic 2152625854 1463962 /opt/OV/bin/OpC/opcuiadm.bin 401429719 89517 /opt/OV/bin/OpC/agtinstall/opcprocs 2491359177 4298 /opt/OV/contrib/OpC/checkuiwww 2958589219 45056 /opt/OV/bin/OpC/install/opctranm 3104848903 9090 /opt/OV/bin/OpC/agtinstall/opcwntprocs 2577854522 20480 /opt/OV/contrib/OpC/strftime 3779187999 69632 /opt/OV/contrib/OpC/opcqschk 3040539629 75379 /opt/OV/bin/OpC/agtinstall/inst.sh 3955351519 57344 /opt/OV/bin/OpC/ovoareqhdlr OVOPC.OVOPC-GUI-ENG,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: 3691133481 326000 /opt/OV/lib/nls/C/opcinstr.cat 2030446527 328057 /opt/OV/lib/nls/C/opcsv.cat OVOPC.OVOPC-LIB,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: 955566827 4415488 /opt/OV/lib/libopcsv_r.sl 2987211109 12288 /opt/OV/lib/libopcassvn.sl OVOPC-OVW.OVOPC-OVW-MGR,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: 72746685 331776 /opt/OV/bin/opcctrlovw 4176751820 155648 /opt/OV/lib/libopcctrlovw.sl OVOPC.OVOPC-GUI,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP: 2699178676 2260992 /opt/OV/lib/libopcui.sl OVOPC-ORA.OVOPC-UX-ORAA,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: 1887367295 147456 /opt/OV/bin/OpC/opcdispm 4258655351 45056 /opt/OV/bin/OpC/opcackmsg 1681834061 94208 /opt/OV/bin/OpC/opcragt 3799483008 151552 /opt/OV/bin/OpC/opcmsgm 838605912 49152 /opt/OV/bin/OpC/opcackmsgs 1059198074 86016 /opt/OV/bin/OpC/opcactm 2843403541 148488 /opt/OV/bin/OpC/opcctlm 731809697 229376 /opt/OV/bin/OpC/opcmsgrd 892577603 2330624 /opt/OV/contrib/OpC/opccfgtest OVOPC-JPN.OVOPC-GUI-JPN,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: 2651914386 352444 /opt/OV/lib/nls/ja_JP.SJIS/opcsv.cat 1503809259 320857 /opt/OV/lib/nls/ja_JP.SJIS/opcinstr.cat OVOPC-ORA.OVOPC-GUI-ORA,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: 2745211051 1765376 /opt/OV/lib/libopcdb.sl 1228002692 585728 /opt/OV/bin/OpC/opcuiop OVOPC-ORA.OVOPC-UX-ORAB,fr=A.06.00,fa=HP-UX_B.11.00_32/64, v=HP: 2554290285 561152 /opt/OV/bin/OpC/opcuiopadm 168179947 884736 /opt/OV/bin/OpC/opccfgupld 2563888879 122880 /opt/OV/bin/OpC/opcuiadm 1322705811 65536 /opt/OV/bin/OpC/opcdbinst 3859915815 61440 /opt/OV/bin/OpC/opcack Patch Conflicts: None Patch Dependencies: s700: 11.00: PHSS_28644 s800: 11.00: PHSS_28644 Hardware Dependencies: None Other Dependencies: None Supersedes: PHSS_29228 Equivalent Patches: None Patch Package Size: 5750 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_30526 5. Run swinstall to install the patch: swinstall -x autoreboot=true -x patch_match_target=true \ -s /tmp/PHSS_30526.depot By default swinstall will archive the original software in /var/adm/sw/save/PHSS_30526. If you do not wish to retain a copy of the original software, include the patch_save_files option in the swinstall command above: -x patch_save_files=false WARNING: If patch_save_files is false when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. For future reference, the contents of the PHSS_30526.text file is available in the product readme: swlist -l product -a readme -d @ /tmp/PHSS_30526.depot To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_30526.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: This is an Intermediate Patch based on the consolidated ITO patch PHSS_28644. You MUST ensure that PHSS_28644 is installed and configured BEFORE PHSS_30526 is installed. You cannot install both PHSS_28644 and PHSS_30526 in the same swinstall session. (A) Patch Installation Instructions ------------------------------- (A1) Stop all OVO processes on your management server; this includes manager processes, communication processes and user-interface processes on the machine. 1. Stop all OVO GUIs (including all Java GUIs connected to this server). Use the "File: Exit" menu bar item. 2. Stop the OVO manager processes: # ovstop opc ovoacomm If any OVO processes are still running, kill them manually: # kill -9 (A2) Install the patch following the standard installation instructions provided above under "Installation Instructions". Observe that you can use opc_backup(5) for backing up your system before installing a patch. (A3) After installing PHSS_30526, restart the OVO processes on your Management Server system: - Restart the OVO Manager processes, and check that the processes are running: # /opt/OV/bin/OpC/opcsv -start # /opt/OV/bin/OpC/opcsv -status (B) Patch Deinstallation Instructions --------------------------------- NOTE: Before removing the patch, stop all OVO server processes, as described in the Patch Installation Instructions (A1).