Patch Name: PHSS_28926 Patch Description: s700_800 11.11 Cluster Object Manager B.02.02.00 Creation Date: 04/03/26 Post Date: 04/04/08 Hardware Platforms - OS Releases: s700: 11.11 s800: 11.11 Products: Cluster Object Manager B.02.02.00 Filesets: Cluster-OM.CM-OM,fr=B.02.02.00,fa=HP-UX_B.11.11_32/64,v=HP CM-Provider-MOF.CM-PROVIDER,fr=B.02.02.00,fa=HP-UX_B.11.11_32/64,v=HP Automatic Reboot?: No Status: General Release Critical: Yes PHSS_28926: ABORT When running CVM usng the VxVM-CVM-pkg, vxclustd may abort during cluster reformation while trying to query the heartbeat network information. Category Tags: defect_repair general_release critical halts_system Path Name: /hp-ux_patches/s700_800/11.X/PHSS_28926 Symptoms: PHSS_28926: 1. When a service configured with SERVICE_FAIL_FAST_ENABLED set to "YES" fails, ServiceGuard Manager may display the node on which the service was running as down while displaying the package as up, until the cluster reforms. 2. When running CVM using the VxVM-CVM-pkg, vxclustd may abort during cluster reformation while trying to query the heartbeat network information: /etc/cmcluster/cvm/VxVM-CVM-pkg.sh.log will show: ERROR: Cluster volume manager is inactive after 60 secs Defect Description: PHSS_28926: 1. Node information is often obtained in a different way from package information, so inconsistent data may be displayed. Resolution: Do extra checking to make sure the information displayed is consistent between nodes and packages. 2. The API to get the cluster configuration information has a check to see if the configuration version has changed since the lookups occurred. It is possible on an SGeRAC cluster that cmgmsd transactions could slip in and increase the version, causing the API call to fail. Resolution: The fix is to turn off this checking for realtime API clients (which is only vxclustd). This is ok because vxclustd does not care if the cmgmsd part of the CDB tree is modified. Enhancement: No SR: 8606294079 8606307795 Patch Files: Cluster-OM.CM-OM,fr=B.02.02.00,fa=HP-UX_B.11.11_32/64,v=HP: /opt/cmom/lib/libcmutil.1 CM-Provider-MOF.CM-PROVIDER,fr=B.02.02.00, fa=HP-UX_B.11.11_32/64,v=HP: /opt/cmom/providers/cmprovider.omp what(1) Output: Cluster-OM.CM-OM,fr=B.02.02.00,fa=HP-UX_B.11.11_32/64,v=HP: /opt/cmom/lib/libcmutil.1: Cluster Monitor Product $Revision: 82.2 $ Cluster Monitor Product Only $Revision: 82.2 $ Build date: Thu Mar 11 16:25:24 PST 2004 Build id: ibld_com_b0202patch_1111_product Build platform: hpux Product Name: HP Cluster Object Manager Version: B.02.02.00 Patch Name: PHSS_28926 CM-Provider-MOF.CM-PROVIDER,fr=B.02.02.00, fa=HP-UX_B.11.11_32/64,v=HP: /opt/cmom/providers/cmprovider.omp: Cluster Management Provider Library Serviceguard Schema 2.1 Build date: Thu Mar 11 16:25:37 PST 2004 Build id: ibld_com_b0202patch_1111_product Build platform: hpux Product Name: HP Cluster Object Manager Version: B.02.02.00 Patch Name: PHSS_28926 cksum(1) Output: Cluster-OM.CM-OM,fr=B.02.02.00,fa=HP-UX_B.11.11_32/64,v=HP: 2891800092 2867200 /opt/cmom/lib/libcmutil.1 CM-Provider-MOF.CM-PROVIDER,fr=B.02.02.00, fa=HP-UX_B.11.11_32/64,v=HP: 2611257626 1200128 /opt/cmom/providers/cmprovider.omp Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_29068: s700: 11.23 s800: 11.23 Patch Package Size: 1140 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_28926 5. Run swinstall to install the patch: swinstall -x autoreboot=true -x patch_match_target=true \ -s /tmp/PHSS_28926.depot By default swinstall will archive the original software in /var/adm/sw/save/PHSS_28926. If you do not wish to retain a copy of the original software, include the patch_save_files option in the swinstall command above: -x patch_save_files=false WARNING: If patch_save_files is false when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. For future reference, the contents of the PHSS_28926.text file is available in the product readme: swlist -l product -a readme -d @ /tmp/PHSS_28926.depot To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_28926.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: For MC/ServiceGuard Clusters: 1) If Veritas CVM is configured within the cluster, halt ServiceGuard on the node the patch is to be installed on. 2) Install this patch on that node. 3) If you have halted the ServiceGuard node (as mentioned in step 1), restart ServiceGuard on that node. 4) Patch needs to be installed on all nodes in the cluster. The above instructions apply to any A.11.15.00 MC/ServiceGuard cluster and include all configurations including those using SGeRAC, SGeSAP, and MetroCluster, for example.