Patch Name: PHSS_27016 Patch Description: s700_800 11.00 OV ITO6.0X MPE Agent Patch A.06.01 Creation Date: 02/06/27 Post Date: 02/07/02 Hardware Platforms - OS Releases: s700: 11.00 s800: 11.00 Products: OpenView IT/Operations 6.0 Filesets: OVOPC-CLT-ENG.OVOPC-MPE-CLT,fr=A.06.00,fa=HP-UX_B.11.00_32/64,v=HP Automatic Reboot?: No Status: General Release Critical: No Category Tags: defect_repair general_release Path Name: /hp-ux_patches/s700_800/11.X/PHSS_27016 Symptoms: PHSS_27016: - SR: 8606207231 request to support MPE/iX 7.0 with VPO - SR: B555010818 Problems with the volinfo script on MPE/ix managed node (the MPE/iX Volume Set Capacity template). volinfo.monitor.ovopc - SR: B555013735 During configuration distribution to MPE agents, one of the following errors might occur: Errors occurred during distribution of the monitors ..(OpC30-1030) The following files could not be replaced ..(OpC30-1097). Defect Description: PHSS_27016: - SR: 8606207231 Configuration files updated so that MPE/iX 7.0 is now supported. - SR: B555010818 patch MPEKX66 and MPE 6.5 altered the output format of the dstat command used by the volinfo script - SR: B555013735 running MPE executables within the actions/commands/monitor distribution of OVO on MPE could not be replaced. for SR's not listed in this section please see the list of symptoms Enhancement: No SR: B555013735 B555010818 8606207231 Patch Files: OVOPC-CLT-ENG.OVOPC-MPE-CLT,fr=A.06.00, fa=HP-UX_B.11.00_32/64,v=HP: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opc_pkg.Z /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opcchka /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opcchks /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opcchkt /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/arcx /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opcstart /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/setfcode /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/sysstrtj /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/vt3k_login /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/vt3k_opcchk /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/vt3k_opcinst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/vt3k_opcstart /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/consdesc /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/opcdf /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/opclpst /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/opcps /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/mi /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/wlog /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/actions/monctrl /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/actions/syncerr /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/actions/whohas /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/abndinfo /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/dbinfo /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/devinfo /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/eofmon /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/lockmon /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/mirrinfo /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/nbstate /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/nbstatus /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/nistatus /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/nsstatus /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/ofmon /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/prntqmon /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/procmon /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/replymon /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/volinfo /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/AgentPlatform what(1) Output: OVOPC-CLT-ENG.OVOPC-MPE-CLT,fr=A.06.00, fa=HP-UX_B.11.00_32/64,v=HP: /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opc_pkg.Z: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opcchka: HP30315 A.05.10 95/02/08 NRT0 Startup routine gethost: A0006000 $ NCS/NCK 1.5.1 $ 37.1 86/07/09 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opcchks: HP30315 A.05.10 95/02/08 NRT0 Startup routine gethost: A0006000 $ NCS/NCK 1.5.1 $ 37.1 86/07/09 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opcchkt: HP30315 A.05.10 95/02/08 NRT0 Startup routine 37.1 86/07/09 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/arcx: HP31508A A.01.01 HP SYMBOLIC DEBUGGER (XDBEND.PU B.SYS) $Revision: 68.6 $ 37.1 86/07/09 /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/opcstart: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/setfcode: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/sysstrtj: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/vt3k_login: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/vt3k_opcchk: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/vt3k_opcinst: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/vt3k_opcstart: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/consdesc: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/opcdf: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/opclpst: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/opcps: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/mi: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/cmds/wlog: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/actions/monctrl: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/actions/syncerr: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/actions/whohas: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/abndinfo: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/dbinfo: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/devinfo: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/eofmon: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/lockmon: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/mirrinfo: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/nbstate: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/nbstatus: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/nistatus: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/nsstatus: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/ofmon: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/prntqmon: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/procmon: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/replymon: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/A.06.01/RPC_NCS/monitor/volinfo: None /var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900/ mpe-ix/AgentPlatform: None cksum(1) Output: OVOPC-CLT-ENG.OVOPC-MPE-CLT,fr=A.06.00, fa=HP-UX_B.11.00_32/64,v=HP: 148022059 12370688 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/opc_pkg.Z 1997045984 627712 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/opcchka 3327891037 623104 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/opcchks 3369326839 40448 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/opcchkt 3544571954 431104 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/arcx 3785746274 877 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/opcstart 2272389336 7050 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/setfcode 356313829 855 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/sysstrtj 3487323952 709 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/vt3k_login 2780327166 11310 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/vt3k_opcchk 2578291296 4712 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/vt3k_opcinst 3332633280 2102 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/vt3k_opcstart 1290471744 2775 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/cmds/consdesc 1283421305 138 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/cmds/opcdf 1515906308 142 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/cmds/opclpst 2372282232 140 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/cmds/opcps 480917921 2048 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/cmds/mi 414830984 1481 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/cmds/wlog 2560398798 3500 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/actions/ monctrl 65529585 3176 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/actions/ syncerr 2455275589 3181 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/actions/whohas 189154278 2279 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ abndinfo 1728645451 4461 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/dbinfo 2017073400 1443 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ devinfo 4046171997 1609 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/eofmon 3011805862 3574 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ lockmon 1608789396 3892 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ mirrinfo 2922683198 1618 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ nbstate 2561707791 13953 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ nbstatus 1383448958 3227 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ nistatus 1325927094 4978 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ nsstatus 3142707610 3943 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ofmon 427331411 1994 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ prntqmon 2884816150 13874 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ procmon 1484068669 1910 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ replymon 3019212819 5434 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/A.06.01/RPC_NCS/monitor/ volinfo 3435478246 3960 /var/opt/OV/share/databases/OpC/mgd_node/ vendor/hp/s900/mpe-ix/AgentPlatform Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: None Patch Package Size: 13960 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_27016 5. Run swinstall to install the patch: swinstall -x autoreboot=true -x patch_match_target=true \ -s /tmp/PHSS_27016.depot By default swinstall will archive the original software in /var/adm/sw/save/PHSS_27016. If you do not wish to retain a copy of the original software, include the patch_save_files option in the swinstall command above: -x patch_save_files=false WARNING: If patch_save_files is false when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. For future reference, the contents of the PHSS_27016.text file is available in the product readme: swlist -l product -a readme -d @ /tmp/PHSS_27016.depot To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_27016.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: BEFORE LOADING THIS PATCH... o It provides bug fixes and enhancements for the VPO A.06.00 Management Server system. o DO NOT use this patch with older releases of ITO, for example versions A.05.00, A.05.11 or A.05.30 (A) Patch Installation Instructions ------------------------------- (A1) Install the patch, following the standard installation instructions. For backing up the system before installing a patch, you may use opc_backup(1m) NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the VPO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWINSTALL. Don't be afraid of the '-x autoreboot=true' option above. There won't be a reboot due to this VPO patch. You can skip this option if you like. If you are running VPO in a MC/ServiceGuard installation: - Note, that only files on the shared disk volume at /var/opt/OV/share will be patched. Therefore install the patch on one cluster node while the shared disks are mounted. The server processes may be running during patch installation. - It is not necessary to install this patch on all cluster nodes. Even if the software inventory on the other cluster nodes will not be updated, the patched files will be available there when the shared disk is switched to them. NOTE: This patch must be installed on the VPO Management Server system, NOT on an VPO Managed Node directly. Changes will take effect on managed nodes by means of VPO Software Distribution (using 'Force Update' if there is already an agent installed on the managed node). See chapter 2 of the VPO Administrator's Reference manual for more information. Be aware that if you redistribute agent software to MC/ServiceGuard cluster nodes you have to update the agent registration on these nodes like this: (this is also documented in the Installation Guide) # INSTDIR=/opt/OV/bin/OpC/install # cp /opt/OV/newconfig/OpC/$INSTDIR/itoagt_sg.reg \ $INSTDIR/itoagt.reg # opcagtreg -add $INSTDIR/itoagt.reg (B) Patch Deinstallation Instructions --------------------------------- (B1) To deinstall the patch PHSS_27016 run swremove: NOTE: MAKE SURE THAT NO AGENT OF THE PLATFORM ADDRESSED BY THIS PATCH IS DISTRIBUTED (either from the ITO Administrator's GUI or from command line using inst.sh) WHILE RUNNING SWREMOVE. If you are running VPO in a MC/ServiceGuard installation make sure to mount the shared disks at the node and only at the node that had them mounted during patch installation. Otherwise restoration of the original files onto the shared disk will fail. # swremove PHSS_27016