Patch Name: PHSS_25983 Patch Description: s700_800 11.11 B1000/B2000/C3X00/J5X00/J6000/J7000 5.0 FW Creation Date: 01/12/19 Post Date: 02/01/11 Hardware Platforms - OS Releases: s700: 11.11 s800: 11.11 Products: N/A Filesets: OS-Core.KERN-RUN,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP Automatic Reboot?: Yes Status: General Release Critical: No (superseded patches were critical) PHSS_24106: OTHER This patch fixes the J6000 external SCSI port definition and makes some changes to I/O addressing. PHSS_23186: OTHER This patch is critical for J6000,J5600,J5000, and J7000 systems. It sets the 1GB DIMM refresh rate to 7.5us to avoid mismatched pairs that can lead to missing memory pairs Category Tags: defect_repair hardware_enablement general_release critical Path Name: /hp-ux_patches/s700_800/11.X/PHSS_25983 Symptoms: PHSS_25983: Same PDC 5.0 firmware as PHSS_24106. DO NOT re-apply to systems that have already been updated. This patch roll is exclusively to address a problem seen when loading PHSS_24106 on an Ignite-UX system. The error message reported is: TEST: run_cmd_wait ("/var/adm/sw/products/PHSS_24106/pfiles/iux_postload") ERROR: Cannot find the utility: lifcp DEBUG: sigchld: wait'ed on process: 904 (last_pid=904) ERROR: The script: "/var/adm/sw/products/PHSS_24106 /pfiles/iux_postload" failed, exit code was 1. The solution was modified to ad /usr/bin to the path in the "iux_postload" file: PATH="${SW_PATH%:}:/usr/sbin:/usr/lbin/sw:/usr/bin" PHSS_24106: This patch fixes the J6000 external SCSI port definition and makes some changes to I/O addressing. PHSS_23186: This patch fixes a possible mismatch of refresh rates between 1GB DIMM pairs. The mismatch would keep the pair of DIMMs from being utilized as a active pair. Defect Description: PHSS_25983: Same PDC 5.0 firmware as PHSS_24106. DO NOT re-apply to systems that have already been updated. This patch roll is exclusively to address a problem seen when loading PHSS_24106 on an Ignite-UX system. The error message reported is: TEST: run_cmd_wait ("/var/adm/sw/products/PHSS_24106/pfiles/iux_postload") ERROR: Cannot find the utility: lifcp DEBUG: sigchld: wait'ed on process: 904 (last_pid=904) ERROR: The script: "/var/adm/sw/products/PHSS_24106/pfiles /iux_postload" failed, exit code was 1. The solution was modified to ad /usr/bin to the path in the "iux_postload" file: PATH="${SW_PATH%:}:/usr/sbin:/usr/lbin/sw:/usr/bin" PHSS_24106: This patch fixes the J6000 external SCSI port definition and makes some changes to I/O addressing. PHSS_23186: This patch will have the system refresh 1GB DIMMs at 7.5us to prevent any mismatch of refresh rates. This patch also allows the ClearFifo function to save the LVDS pat enable value. SR: 8606107507 Patch Files: OS-Core.KERN-RUN,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP: /usr/conf/reflash /usr/conf/pdc.wrap /usr/conf/modelstr what(1) Output: OS-Core.KERN-RUN,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP: /usr/conf/reflash: Firmware reflash utility version 1.1 for 9000/785 B/ C/J PCXW/W+ workstations /usr/conf/pdc.wrap: Data Hdr A.00.01 Build user: Firmware Builder Build login: fwbtr@firmbert.fc.hp.com Build directory: /home/fwbtr/work/sprockets/src/bch Build date: Thu Jan 11 17:24:28 MST 2001 Build type: wide Makerom options: Build options: -USIM -USIM_FAST -USIM_CANT -UCACHE_LINE_32B -UELAPSED_TIME -UKEY232 -UTEMP_BIKE -UDEBUG_STACK -UTEMP_IODC_TRACE -UTEMP_DISABLE_DWIDE -DTEMP_LDB_CONSOLE -DTEMP_NO_8051 -UNO_COHERENT -DTEMP_PDC_TRACE -UTEMP_PSEUDO_BOOT -DTEMP_TRACE -UPCI_TRACE -ULAN_DEBUG_ENTRY_POINTS -DDUET -DTEMP_HPUX_64BITS /usr/conf/modelstr: modelstr $Revision: 1.1 $ PATCH_11.00 (PHCO_15048) PATCH-PHCO_17381 for 10.20; for 10.30, 11.x compatibility libc.a_ID@@/main/r10dav/libc_dav/15 /ux/core/libs/libc/archive_pa1/libc.a_ID Mar 9 1999 13:52:37 cksum(1) Output: OS-Core.KERN-RUN,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP: 2713464597 24770 /usr/conf/reflash 101534573 1049856 /usr/conf/pdc.wrap 1596174293 12348 /usr/conf/modelstr Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: 9000/785/B1000 9000/785/B2000 9000/785/C3000 9000/785/C3600 9000/785/J5000 9000/785/J5600 9000/785/J6000 9000/785/J7000 Other Dependencies: None Supersedes: PHSS_23186 PHSS_24106 Equivalent Patches: PHSS_25981: s700: 10.20 PHSS_25982: s700: 11.00 Patch Package Size: 1090 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_25983 5. Run swinstall to install the patch: swinstall -x autoreboot=true -x patch_match_target=true \ -s /tmp/PHSS_25983.depot By default swinstall will archive the original software in /var/adm/sw/save/PHSS_25983. If you do not wish to retain a copy of the original software, include the patch_save_files option in the swinstall command above: -x patch_save_files=false WARNING: If patch_save_files is false when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. For future reference, the contents of the PHSS_25983.text file is available in the product readme: swlist -l product -a readme -d @ /tmp/PHSS_25983.depot To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_25983.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: This patch will only install and update the firmware on these systems: 9000/785/B1000 9000/785/B2000 9000/785/C3000 9000/785/C3600 9000/785/J5000 9000/785/J5600 9000/785/J6000 9000/785/J7000 If the installed system firmware is more recent than the firmware provided in the patch, the system firmware will not be modified when the patch is installed. If you wish to install the patch on a different system even though it does not apply, you can force the installation of the patch by touching the file '/tmp/force_patch_install' before installing the patch. This may be useful when creating a 'golden' archive image for Ignite-UX that may be used on several different hardware platforms. If the patch is installed on a system other than those listed above, it will not modify the system firmware so no harm will occur.