Patch Name: PHSS_23112 Patch Description: s700_800 11.00 OV OB3.10.FX patch - CS packet Creation Date: 01/03/19 Post Date: 01/04/12 Hardware Platforms - OS Releases: s700: 11.00 s800: 11.00 Products: OmniBackII A.03.10.FX Filesets: OMNIBACK-II.OMNI-CS,fr=A.03.10.FX,fa=HP-UX_B.11.00_32/64,v=HP Automatic Reboot?: No Status: General Release Critical: No Category Tags: defect_repair general_release Path Name: /hp-ux_patches/s700_800/11.X/PHSS_23112 Symptoms: PHSS_23112: Id = NSMex04057 Execution of command "omnirpt -report used_media -timeframe " results in the following error message: "DB[4] internal error [-16] record not connected to set". Defect Description: PHSS_23112: Id = NSMex04057 Listing of objects failed for the objects that have been purged from the database, because there is no link between objects and object versions. Resolution: Fix is implemented in libob2ecbd.sl. SR: H555003704 Patch Files: OMNIBACK-II.OMNI-CS,fr=A.03.10.FX,fa=HP-UX_B.11.00_32/64, v=HP: /opt/omni/lib/libob2ecdb.sl what(1) Output: OMNIBACK-II.OMNI-CS,fr=A.03.10.FX,fa=HP-UX_B.11.00_32/64, v=HP: /opt/omni/lib/libob2ecdb.sl: None cksum(1) Output: OMNIBACK-II.OMNI-CS,fr=A.03.10.FX,fa=HP-UX_B.11.00_32/64, v=HP: 1298487434 877493 /opt/omni/lib/libob2ecdb.sl Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_23111: s700: 10.00 10.01 10.10 10.20 s800: 10.00 10.01 10.10 10.20 Patch Package Size: 880 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_23112 5. Run swinstall to install the patch: swinstall -x autoreboot=true -x patch_match_target=true \ -s /tmp/PHSS_23112.depot By default swinstall will archive the original software in /var/adm/sw/save/PHSS_23112. If you do not wish to retain a copy of the original software, use the patch_save_files option: swinstall -x autoreboot=true -x patch_match_target=true \ -x patch_save_files=false -s /tmp/PHSS_23112.depot WARNING: If patch_save_files is false when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. For future reference, the contents of the PHSS_23112.text file is available in the product readme: swlist -l product -a readme -d @ /tmp/PHSS_23112.depot To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_23112.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: PHSS_23112: NOTE! This patch only applies to the product "OmniBack II, Version A.03.10_FX EMC Serverless Backup" It needs not - and actually cannot - be installed on any system running in an ordinary OmniBack 3.10 Cell. NOTE! This Patch has to be installed on the Cell Manager host. OmniBack II server must be shutdown before installing the patch. Use the following command for shutting down the server: "/opt/omni/sbin/omnisv.sh stop". After the installation is complete, restart OmniBack II server using "/opt/omni/sbin/omnisv.sh start".