Patch Name: PHKL_27734 Patch Description: s700_800 11.11 Data page fault in vx_isumpush() Creation Date: 02/09/05 Post Date: 03/01/09 Hardware Platforms - OS Releases: s700: 11.11 s800: 11.11 Products: N/A Filesets: JFS.VXFS-BASE-KRN,fr=B.11.11,fa=HP-UX_B.11.11_32,v=HP JFS.VXFS-BASE-KRN,fr=B.11.11,fa=HP-UX_B.11.11_64,v=HP Automatic Reboot?: Yes Status: General Release Critical: Yes PHKL_27734: PANIC Category Tags: defect_repair general_release critical panic Path Name: /hp-ux_patches/s700_800/11.X/PHKL_27734 Symptoms: PHKL_27734: ( SR:8606166688 CR:JAGad35975 ) Corrupted VxFS filesystem may panic the system. Stack of the panic thread will look like, panic+0x6c report_trap_or_int_and_panic+0x94 trap+0xfe4 nokgdb+0x8 vx_isumpush+0x8 vx_sumpushfset+0xa8 vx_fsetupdate+0x6c vx_sync1+0x54 vx_sync0+0x18 vx_walk_fslist+0x7c vx_sync+0x58 update+0x4c tsync+0x164 syscall+0x750 $syscallrtn+0x0 Defect Description: PHKL_27734: ( SR:8606166688 CR:JAGad35975 ) When a filesystem is corrupted, incore data strucures and data on disk may differ and dereferencing them on a corrupted filesystem may panic the system. Resolution: Cross check whether the incore data and data on disk match so that a filesystem corruption could be detected and the filesystem could be disabled, thus avoiding a system crash. Enhancement: No SR: 8606166688 Patch Files: JFS.VXFS-BASE-KRN,fr=B.11.11,fa=HP-UX_B.11.11_32,v=HP: /usr/conf/lib/libvxfs.a(vx_fsetsubr.o) JFS.VXFS-BASE-KRN,fr=B.11.11,fa=HP-UX_B.11.11_64,v=HP: /usr/conf/lib/libvxfs.a(vx_fsetsubr.o) what(1) Output: JFS.VXFS-BASE-KRN,fr=B.11.11,fa=HP-UX_B.11.11_32,v=HP: /usr/conf/lib/libvxfs.a(vx_fsetsubr.o): vx_fsetsubr.c $Date: 2002/08/19 06:03:07 $Revision: r11.11/1 PATCH_11.11 (PHKL_27734) JFS.VXFS-BASE-KRN,fr=B.11.11,fa=HP-UX_B.11.11_64,v=HP: /usr/conf/lib/libvxfs.a(vx_fsetsubr.o): vx_fsetsubr.c $Date: 2002/08/19 06:03:07 $Revision: r11.11/1 PATCH_11.11 (PHKL_27734) cksum(1) Output: JFS.VXFS-BASE-KRN,fr=B.11.11,fa=HP-UX_B.11.11_32,v=HP: 1462223229 28964 /usr/conf/lib/libvxfs.a(vx_fsetsubr.o) JFS.VXFS-BASE-KRN,fr=B.11.11,fa=HP-UX_B.11.11_64,v=HP: 1716328713 52064 /usr/conf/lib/libvxfs.a(vx_fsetsubr.o) Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHKL_24010: s700: 11.00 s800: 11.00 Patch Package Size: 100 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHKL_27734 5. Run swinstall to install the patch: swinstall -x autoreboot=true -x patch_match_target=true \ -s /tmp/PHKL_27734.depot By default swinstall will archive the original software in /var/adm/sw/save/PHKL_27734. If you do not wish to retain a copy of the original software, include the patch_save_files option in the swinstall command above: -x patch_save_files=false WARNING: If patch_save_files is false when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. For future reference, the contents of the PHKL_27734.text file is available in the product readme: swlist -l product -a readme -d @ /tmp/PHKL_27734.depot To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHKL_27734.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: None