Patch Name: PHCO_23263 Patch Description: s700_800 11.11 HP AutoRAID Manager cumulative patch Creation Date: 01/03/05 Post Date: 01/03/16 Hardware Platforms - OS Releases: s700: 11.11 s800: 11.11 Products: N/A Filesets: OS-Core.ARRAY-MGMT,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP OS-Core.ADMN-ENG-A-MAN,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP Automatic Reboot?: No Status: General Release Critical: Yes PHCO_23263: OTHER Patch provides critical functionality for use of HP AutoRAID devices. Category Tags: defect_repair hardware_enablement enhancement general_release critical Path Name: /hp-ux_patches/s700_800/11.X/PHCO_23263 Symptoms: PHCO_23263: 1. JAGad34994 - 'arraymgr -s start' gives timeout error 2. JAGad27621 - ARM Unable to Download to Disk due to SCSI Disk FW convergence 3. JAGad26663 - Cannot Download using Array Alias ** B.11.11.14 - As Issued ** Defect Description: PHCO_23263: 1. Description: JAGad34994 - 'arraymgr -s start' gives timeout error An SCLT_INCOMPLETE error was blocking receipt of proper READY status from the array. A timer was changed to allow array to reach full READY before SCSI response is tested. 2. Description: JAGad27621 - ARM Unable to Download to Disk due to SCSI Disk FW convergence between purchasing divisions within HP. New entry placed into download.cpp to trigger on combination of Vendor ID="HP" and Product Revision="HP". This path uses Mode 7 with unnumbered buffers sized at 32768 bytes. 3. Description: JAGad26663 - Cannot Download using Array Alias Man pages corrected for both HP-UX and MPE to reflect actual functionality. Never a specified requirement for 'download' to address an array by an Alias. ** B.11.11.14 - As Issued ** SR: 8606165702 8606158291 8606157331 Patch Files: OS-Core.ARRAY-MGMT,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP: /opt/hparray/bin/ARMServer /opt/hparray/bin/arraycfg /opt/hparray/bin/arraydsp /opt/hparray/bin/arrayfmt /opt/hparray/bin/arraylog /opt/hparray/bin/arraymgr /opt/hparray/bin/arrayrbld /opt/hparray/bin/arrayrecover /opt/hparray/bin/drivetest /opt/hparray/bin/dteststat /opt/hparray/bin/logprint /opt/hparray/bin/download /opt/hparray/lib/nls/msg/C/ARMServer.cat /opt/hparray/lib/nls/msg/C/hpraidcl.cat /opt/hparray/lib/nls/msg/C/hprecover.cat /opt/hparray/lib/nls/msg/C/oemmsg01.cat /opt/hparray/lib/nls/msg/C/fwerrcod.cat OS-Core.ADMN-ENG-A-MAN,fr=B.11.11,fa=HP-UX_B.11.11_32/64, v=HP: /usr/share/man/man1m.Z/ARMServer.1m /usr/share/man/man1m.Z/arraycfg.1m /usr/share/man/man1m.Z/arraydsp.1m /usr/share/man/man1m.Z/arrayfmt.1m /usr/share/man/man1m.Z/arraylog.1m /usr/share/man/man1m.Z/arraymgr.1m /usr/share/man/man1m.Z/arrayrbld.1m /usr/share/man/man1m.Z/arrayrecover.1m /usr/share/man/man1m.Z/drivetest.1m /usr/share/man/man1m.Z/dteststat.1m /usr/share/man/man1m.Z/logprint.1m /usr/share/man/man1m.Z/download.1m what(1) Output: OS-Core.ARRAY-MGMT,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP: /opt/hparray/bin/ARMServer: +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Server | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - HP Shim | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company $Header: devlists.c,v 80.1 96/11/19 09:31:03 ssa Exp $ $Header: common.c,v 1.6 96/04/11 09:31:13 hmgr Exp $ $Header: dlib10.c,v 1.15 96/04/08 13:41:31 hmgr Exp $ +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/arraycfg: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Client | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/arraydsp: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Client | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/arrayfmt: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Client | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/arraylog: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Client | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/arraymgr: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Client | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/arrayrbld: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Client | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/arrayrecover: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Standalone Utility | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company $Header: devlists.c,v 80.1 96/11/19 09:31:03 ssa Exp $ $Header: common.c,v 1.6 96/04/11 09:31:13 hmgr Exp $ $Header: dlib10.c,v 1.15 96/04/08 13:41:31 hmgr Exp $ /opt/hparray/bin/download: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Standalone Utility | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company $Header: devlists.c,v 80.1 96/11/19 09:31:03 ssa Exp $ $Header: common.c,v 1.6 96/04/11 09:31:13 hmgr Exp $ $Header: dlib10.c,v 1.15 96/04/08 13:41:31 hmgr Exp $ /opt/hparray/bin/drivetest: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Client | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/dteststat: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Client | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company +-HP AutoRAID Manager - Server Interface Component | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/bin/logprint: HP92453-02A.11.00 HP-UX SYMBOLIC DEBUGGER (END.O ILP 32) $Revision: 75.02 $ +-HP AutoRAID Manager | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-HP AutoRAID Manager - Standalone Utility | Version: B.11.11.15 | (built for: HP-UX B.11.11 on B.11.00 2001/03/05 14 :56:07) +-Copyright (c) 1995 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/ARMServer.cat: HP AutoRAID [B.11.11.15] ARMServer.cat $Revision: 1. 16 $ Built for HP-UX B.11.11 on B.11.00 2001/03/05 14:56: 07 PM MDT (c) Copyright 1995 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/fwerrcod.cat: HP AutoRAID [B.11.11.15] fwerrcod.cat $Revision: 1.9 $ Built for HP-UX B.11.11 on B.11.00 2001/03/05 14:56: 07 PM MDT (c) Copyright 1995 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/hpraidcl.cat: HP AutoRAID [B.11.11.15] hpraidcl.cat $Revision: 1.6 0 $ Built for HP-UX B.11.11 on B.11.00 2001/03/05 14:56: 07 PM MDT (c) Copyright 1995 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/hprecover.cat: HP AutoRAID [B.11.11.15] hprecover.cat $Revision: 1. 9 $ Built for HP-UX B.11.11 on B.11.00 2001/03/05 14:56: 07 PM MDT (c) Copyright 1997 Hewlett-Packard Company /opt/hparray/lib/nls/msg/C/oemmsg01.cat: HP AutoRAID [B.11.11.15] oemmsg01.cat $Revision: 1.6 $ Built for HP-UX B.11.11 on B.11.00 2001/03/05 14:56: 07 PM MDT (c) Copyright 1995 Hewlett-Packard Company OS-Core.ADMN-ENG-A-MAN,fr=B.11.11,fa=HP-UX_B.11.11_32/64, v=HP: /usr/share/man/man1m.Z/ARMServer.1m: None /usr/share/man/man1m.Z/arraycfg.1m: None /usr/share/man/man1m.Z/arraydsp.1m: None /usr/share/man/man1m.Z/arrayfmt.1m: None /usr/share/man/man1m.Z/arraylog.1m: None /usr/share/man/man1m.Z/arraymgr.1m: None /usr/share/man/man1m.Z/arrayrbld.1m: None /usr/share/man/man1m.Z/arrayrecover.1m: None /usr/share/man/man1m.Z/download.1m: None /usr/share/man/man1m.Z/drivetest.1m: None /usr/share/man/man1m.Z/dteststat.1m: None /usr/share/man/man1m.Z/logprint.1m: None cksum(1) Output: OS-Core.ARRAY-MGMT,fr=B.11.11,fa=HP-UX_B.11.11_32/64,v=HP: 435135516 2503400 /opt/hparray/bin/ARMServer 2628750421 921256 /opt/hparray/bin/arraycfg 3874377849 1057448 /opt/hparray/bin/arraydsp 2230538382 910880 /opt/hparray/bin/arrayfmt 11055629 951792 /opt/hparray/bin/arraylog 3765355394 951808 /opt/hparray/bin/arraymgr 816260665 923464 /opt/hparray/bin/arrayrbld 2478800070 732560 /opt/hparray/bin/arrayrecover 3444336831 351472 /opt/hparray/bin/download 1352572968 910672 /opt/hparray/bin/drivetest 2950648326 915688 /opt/hparray/bin/dteststat 520880561 809912 /opt/hparray/bin/logprint 2637014586 7641 /opt/hparray/lib/nls/msg/C/ARMServer.cat 789628875 9088 /opt/hparray/lib/nls/msg/C/fwerrcod.cat 1289535679 54536 /opt/hparray/lib/nls/msg/C/hpraidcl.cat 1059049580 6425 /opt/hparray/lib/nls/msg/C/hprecover.cat 805517267 1391 /opt/hparray/lib/nls/msg/C/oemmsg01.cat OS-Core.ADMN-ENG-A-MAN,fr=B.11.11,fa=HP-UX_B.11.11_32/64, v=HP: 52779712 2407 /usr/share/man/man1m.Z/ARMServer.1m 391418371 5569 /usr/share/man/man1m.Z/arraycfg.1m 1378240874 9248 /usr/share/man/man1m.Z/arraydsp.1m 1776118836 3203 /usr/share/man/man1m.Z/arrayfmt.1m 3861880079 3847 /usr/share/man/man1m.Z/arraylog.1m 2525358973 8249 /usr/share/man/man1m.Z/arraymgr.1m 486677178 3892 /usr/share/man/man1m.Z/arrayrbld.1m 359571123 3746 /usr/share/man/man1m.Z/arrayrecover.1m 3709343760 3446 /usr/share/man/man1m.Z/download.1m 891404485 3649 /usr/share/man/man1m.Z/drivetest.1m 1347694920 3199 /usr/share/man/man1m.Z/dteststat.1m 3041072082 3296 /usr/share/man/man1m.Z/logprint.1m Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: This patch provides the utilities for the HP Array with AutoRAID. It requires the OS-Core.C2400-UTIL fileset to be installed for the array status to monitored properly. To use the utilities an HP AutoRAID array must be connected and configured to the system. Supersedes: None Equivalent Patches: PHCO_23261: s700: 10.01 10.10 10.20 10.30 s800: 10.01 10.10 10.20 10.30 PHCO_23262: s700: 11.00 11.10 s800: 11.00 11.10 Patch Package Size: 11880 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHCO_23263 5. Run swinstall to install the patch: swinstall -x autoreboot=true -x patch_match_target=true \ -s /tmp/PHCO_23263.depot By default swinstall will archive the original software in /var/adm/sw/save/PHCO_23263. If you do not wish to retain a copy of the original software, use the patch_save_files option: swinstall -x autoreboot=true -x patch_match_target=true \ -x patch_save_files=false -s /tmp/PHCO_23263.depot WARNING: If patch_save_files is false when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. For future reference, the contents of the PHCO_23263.text file is available in the product readme: swlist -l product -a readme -d @ /tmp/PHCO_23263.depot To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHCO_23263.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: None