Patch Name: PHSS_1894 Patch Description: The second patch for NLIO 8.2 (A.08.20E 08/24/92). Symptoms: PCF fonts are not compatible with old SNF fonts. Max_bound.ascent and max_bound.descent value of jpn.8x18, jeuc.8x18, jpn.12x24, jeuc.12x24, jpn.16x32 and jeuc.16x32 are changed. Because of this change, each character patterm is displayed at the different position on application window. Fix: Changed PCF fonts to have the same value with SNF fonts. Path Name: /hp-ux_patches/s700/9.X/PHSS_1894 Effective Date: 930118 Patch Files: /usr/lib/X11/fonts/hp_japanese/75dpi/jeuc.12x24.pcf /usr/lib/X11/fonts/hp_japanese/75dpi/jeuc.16x32.pcf /usr/lib/X11/fonts/hp_japanese/75dpi/jeuc.8x18.pcf /usr/lib/X11/fonts/hp_japanese/75dpi/jpn.12x24.pcf /usr/lib/X11/fonts/hp_japanese/75dpi/jpn.16x32.pcf /usr/lib/X11/fonts/hp_japanese/75dpi/jpn.8x18.pcf SR/APR#: None. "what" string/timestamp: jeuc.12x24 A.08.20K 12/21/92 jeuc.16x32 A.08.20K 12/21/92 jeuc.8x18 A.08.20K 12/21/92 jpn.12x24 A.08.20K 12/21/92 jpn.16x32 A.08.20K 12/21/92 jpn.8x18 A.08.20K 12/21/92 "sum" output: 35996 42 jeuc.12x24.pcf 5991 50 jeuc.16x32.pcf 48470 36 jeuc.8x18.pcf 35435 42 jpn.12x24.pcf 5430 50 jpn.16x32.pcf 47873 36 jpn.8x18.pcf Dependencies: This patch should be applied to NLIO 8.2 (A.08.20E 08/24/92). Supersedes: None. Patch Package Size: 164 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_1894). To install this patch do the following: 1) Run /etc/update (Note: you must be root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHSS_1894.updt" (this assumes that you are in the directory where PHSS_1894.updt has been placed). You must type in the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHSS_1894/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_1894.text file to /system/PHSS_1894 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHSS_1894.updt of=/dev/rmt/0m bs=2048