Patch Name: PHSS_1614 Patch Description: Fix ImageView 24 plane support problem for HP-UX 9.0 X color allocation problem running imageview on 24 plane displays running on hp-ux 9.0. This causes imageview to abort and not display image files. Programs affected: /usr/bin/X11/imageview File Fixed: /usr/bin/X11/imageview Symptoms: The imageview program will terminate or abort when it is run on 700's that have 24 planes. The X server will report that it could not query colors successfully. The fix involves a change to the X color allocation logic within imageview. Path Name: /hp-ux_patches/s700/9.X/PHSS_1614 Effective Date: 921013 Patch Files: /usr/bin/X11/imageview SR/APR#: None "what" string/timestamp: HP imageview V2.0 IC2_9.0 (bl22) "sum" output: 53404 232 imageview Dependencies: This patch should be applied to HP-UX 9.0. Supersedes: None Patch Package Size: 154 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_1614). To install this patch do the following: 1) Run /etc/update (Note: you must be root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHSS_1614.updt" (this assumes that you are in the directory where PHSS_1614.updt has been placed). You must type in the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHSS_1614/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_1614.text file to /system/PHSS_1614 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHSS_1614.updt of=/dev/rmt/0m bs=2048