Patch Name: PHNE_4376 Patch Description: s700 9.X fixes HIPPI driver defects (SR number: 4701248716) Trap 18 crash dump upon heavy LLA and IFNET traffic. The problem can occur also with LLA traffic only. Kernel Stack trace: panic+0x2c ( arguments not stored ) pc=0x133eb0, pfmp=0x7ffe7438, psp=0x7ffe7458 trap+0x810 ( arguments not stored ) pc=0xb5388, pfmp=0x7ffe7338, psp=0x7ffe7358 trap marker save state 0x7ffe7128 sp 0x7ffe7358 framesize 0x230 hippi_sch_copy_pkt+0x1dc ( 0x02013000 ,0x00000001 , 0x000e0768 ,0x46000000 ) pc=0x4faec, pfmp=0x7ffe7088, psp=0x7ffe70a8 hippi_sch_xmit_sm+0x450 ( 0x02013000 ,0x00000010 , 0x02265e2c ,0x7ffe6f20 ) pc=0x4f2ec, pfmp=0x7ffe6f48, psp=0x7ffe6f68 Internal error for the test environment. The problem detected when inspecting code of the output module. Potential error in the oubound path. Hardware state down when intensive LLA traffic. The problem occurs when having intensive LLA and IP traffic over HIPPI. lanscan command detect that hardware is down. LLA traffic is stopped and write call returns ENETDOWN error. A disaster problem is logged indicating an unexpected event in the outbound state machine. SR#: 4701248716 Path Name: /hp-ux_patches/s700/9.X/PHNE_4376 Effective Date: 94/06/15 OS Release: 9.01 9.03 9.05 Reboot Required: Yes Patch Files: /etc/conf/libhippi.a "what" string/timestamp: J2069A - HIPPI/9000 ; libhippi.a (A.00.01) "sum" output: For 9.01 14872 275 /etc/conf/libhippi.a For 9.03, 9.05 28141 275 /etc/conf/libhippi.a Dependencies: It is recommended to install the following patches to get fixes for some subsystems defects revealed by HIPPI: - XPORT: PHNE_3938 (9.01) / PHNE_3939 (9.03/9.05) - NFS: PHNE_4021 (9.01) / PHNE_4022 (9.03/9.05) Supersedes: None Patch Package Size: 1414 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. After getting the patch onto your machine, unshar the patch (sh PHNE_4376) To install this patch do the following: 1) Run /etc/update (Note: you must be root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: PHNE_4376.updt" assuming you are in the directory where PHNE_4376.updt has been placed. In some versions, you may need to enter the absolute path name. In others, the default "/dev/rmt/0m" may not appear in the field as default. 5) Press "Done". 6) Move to the "Select All Filesets on Source Media" line and press "Return". The customized script that update runs will move the original software to /system/PHNE_4376/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHNE_4376.text file to /system/PHNE_4376 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHNE_4376.updt of=/dev/rmt/0m bs=2048