Patch Name: PHNE_4288 Patch Description: s700 9.0[35] Token Ring 9000/712 patch This patch fixes a driver and card reset problem (nettl log error 1302 - hardware open error) on the 712/80, which requires the user to reboot the system. This patch also fixes a cable disconnect problems for the Token Ring 9000/712 product, which forces the user to reset the driver and card. The user will observe a nettl log error of 1303 - hardware close error. Path Name: /hp-ux_patches/s700/9.X/PHNE_4288 Effective Date: 940531 OS Release: 9.03 9.05 Reboot Required: Yes Patch Files: /etc/conf/libtoken.a(token3.o) /usr/lib/nls/C/fmtTOKEN.cat /usr/lib/libfmtTOKEN.sl SR#: 5003198242 5003198259 "what" string/timestamp: fmtTOKEN.cat: libfmtTOKEN.sl: TOKEN: Version: A.09.00 $Date: 93/12/22 12:22:23 $ token3.o: FILESET TOKEN3: lib token: Version: A.09.00 token3.c $Revision: 1.26.393.18 $ $Date: 94/05/31 16:03:51 $ PHNE_4288 "sum" output: 37457 13 fmtTOKEN.cat 9851 40 libfmtTOKEN.sl 63227 109 token3.o Dependencies: Requires Token Ring product installed. Supersedes: PHNE_3552 Patch Package Size: 144 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHNE_4288). To install this patch do the following: 1) Run /etc/update (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHNE_4288.updt" (this assumes that you are in the /tmp directory where PHNE_4288.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHNE_4288/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHNE_4288.text file to /system/PHNE_4288 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHNE_4288.updt of=/dev/rmt/0m bs=2048