Patch Name: PHSS_3538 Patch Description: s700 8.X R4 xterm(1) January Periodic patch This patch fixes the following new problem(s). - Updated to latest xterm released on HP-UX 9.0 - Background color does not follow changes to VUE 2.01 color schemes. - Orphaned xterm processes are left running after logging out from a VUE 2.01 session on an X-terminal. (SR# 5003-169326) - Versions of xterm replaced by patches are not protected from use by non-root users. Previously released patch changes retained: PHSS_3408 93/11/23 - Updated to latest xterm released on HP-UX 9.0 - Security hole in xterm logging when setuid root. (Logging is now disabled). - LINES and COLUMNS not set properly under csh(1) PHSS_1679 92/10/29 92/10/29 - Rolled the xterm released for HP-UX 9.0 back to all HP-UX 8.* releases for series 300, 400, 700, and 800. In addition to the fixes listed below, this "patched" xterm resolves many other problems found in the HP-UX 8.* versions of xterm. 92/10/29 - Resolved cut and paste problems encountered when pasting large blocks of data. Path Name: /hp-ux_patches/s700/8.X/PHSS_3538 Effective Date: 94/01/11 OS Release: 8.01 8.05 8.07 Reboot Required: No Patch Files: /usr/bin/X11/xterm /usr/man/man1.Z/xterm.1 SR/APR#: SR 1653-072959 5003-035899 5003-169326 "what" string/timestamp: xterm: X Window System, Version 11 R4 Patched xterm: $Revision: 1.9 $ xterm.1: "sum" output: 40103 336 xterm 28338 52 xterm.1 Dependencies: None Supersedes: PHSS_0784 PHSS_1628 PHSS_1679 PHSS_3408 Patch Package Size: 236 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_3538). To install this patch do the following: 1) Run /etc/update (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHSS_3538.updt" (this assumes that you are in the /tmp directory where PHSS_3538.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHSS_3538/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_3538.text file to /system/PHSS_3538 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHSS_3538.updt of=/dev/rmt/0m bs=2048