Patch Name: PHSS_3089 Patch Description: s700 8.07 FORTRAN E format does not work properly FORTRAN E format doesn't work properly with exponents >99 Path Name: /hp-ux_patches/s700/8.X/PHSS_3089 Effective Date: 930907 Patch Files: /usr/lib/libcl.a /usr/lib/libcl.sl SR#: 5000-699744 E format doesn't work properly when printing REAL*8 with exponent >99 (dup of 4701-012427) 5003-033472 Cannot open nfs file unless write permission set 1653-027177 I/O error 908 when attempting to open an existing file for read. (dup of 5003-033472) 4701-026963 Extra chars in STOP string using S800 object files and 8.05 libcl (S700) "what" string/timestamp: /usr/lib/libcl.a: libcl.a IF2 version A.08.70.03 07/14/93 /usr/lib/libcl.sl: libcl.sl IF2 version A.08.70.03 07/14/93 "sum" output: 54570 2489 /usr/lib/libcl.a 642 2111 /usr/lib/libcl.sl Dependencies: Customers who already have patched libcl's will overwrite those patches with this one unless they move the affected libraries to another place or name (and recompile any programs that use the shared libcl). Supersedes: PHSS_2185 Patch Package Size: 2386 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_3089). To install this patch do the following: 1) Run /etc/update (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHSS_3089.updt" (this assumes that you are in the /tmp directory where PHSS_3089.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHSS_3089/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_3089.text file to /system/PHSS_3089 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHSS_3089.updt of=/dev/rmt/0m bs=2048