Patch Name: PHSS_1727 Patch Description: PVRX timeout on large PHIGS SOFA or polygon_with_data sets. PVRX times out on some large PHIGS SOFA or polygon_with_data sets. Path Name: /hp-ux_patches/s700/8.X/PHSS_1727 Effective Date: 921110 Patch Files: libdd98705.a libdd98705.sl SR/APR#: 5000-68486-0 "what" string/timestamp: libdd98705.a: STARBASE HP-UX 8.07 A.08.07 10/09/91 libdd98705.a $Revision: 402.1.1.1 $ STARBASE HP-UX 8.07 PHSS_1727 92/11/06 polyhedron/SOFAS timeout libdd98705.sl: STARBASE HP-UX 8.07 A.08.07 10/09/91 libdd98705.a $Revision: 402.1.1.1 $ STARBASE HP-UX 8.07 PHSS_1727 92/11/06 polyhedron/SOFAS timeout "sum" output: 8021 448 libdd98705.a 64901 576 libdd98705.sl Dependencies: This patch should be applied to HP-UX 8.07 along with PHSS_1493 to remove both cases of timeouts. Supersedes: None. Patch Package Size: 553 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_1727). To install this patch do the following: 1) Run /etc/update (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHSS_1727.updt" (this assumes that you are in the /tmp directory where PHSS_1727.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHSS_1727/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_1727.text file to /system/PHSS_1727 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHSS_1670.updt of=/dev/rmt/0m bs=2048