Patch Name: PHSS_1590 Patch Description: Not reporting Raw IO & diskless startup failure SR D500-140913 Logical I/O is reported incorrectly if Oracle is started prior to starting midaemon and GlancePlus/UX. A possible indicator of this problem is that physical I/O will be greater than logical I/O as shown in the Disk Detail screen. It will also show a high cache hit rate. Refer to Teck call ID W1745878. This raw IO is not reported. SR D500-140962 The A.08.11 mi_lib has a problem which causes glance and scopeux to fail during initialization on diskless clients which do NOT have either a locally-mounted filesystem or local swap. The error seen in the glance.err or status.scope file is: get_hfs_init: no HFS vfs entry found This problem has been corrected. Path Name: /hp-ux_patches/s700/8.X/PHSS_1590 Effective Date: 921006 Patch Files: glance midaemon 800 HPUX/MI-A HPPerf Tools,midaemon A.08.15 10/05/92 COPYRIGHT (c) Hewlett-Packard Co. 1991 800 HPUX/MI-A HPPerf Tools,dsetup A.08.00 5/16/91 800 HPUX/MI-A HPPerf Tools,shared A.08.01 09/11/91 SR#: D500-140913, D500-140962 "what" string/timestamp: glance: midaemon: "sum" output: 45910 792 glance 20848 240 midaemon Dependencies: None. Supersedes: None. Patch Package Size: 564 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_1590). To install this patch do the following: 1) Run /etc/update (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: /tmp/PHSS_1590.updt" (this assumes that you are in the /tmp directory where PHSS_1590.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow the standard directions for update. The customized script that update runs will move the original software to /system/PHSS_1590/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_1590.text file to /system/PHSS_1590 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHSS_1590.updt of=/dev/rmt/0m bs=2048