Patch Name: PHSS_1080 Patch Description: Patch to dd98736/766 for xform engine hang on gopen Path Name: /hp-ux_patches/s700/8.X/PHSS_1080 Effective Date:920505 Patch Files: /usr/lib/libdd98736.a /usr/lib/libdd98736.sl /usr/lib/libdd98766.a /usr/lib/libdd98766.sl SR/APR#: None "what" string/timestamp: bdd98736.a: STARBASE HP-UX 8.07 A.08.07 10/09/91 libdd98736.a $Revision: 402.1.1.1 $ PATCH_8.07 genesis_h.o RoboCAD hang fix 92May05 libdd98736.sl: STARBASE HP-UX 8.07 A.08.07 10/09/91 libdd98736.a $Revision: 402.1.1.1 $ PATCH_8.07 genesis_h.o RoboCAD hang fix 92May05 libdd98766.a: STARBASE HP-UX 8.07 A.08.07 10/09/91 libdd98736.a $Revision: 402.1.1.1 $ PATCH_8.07 genesis_h.o RoboCAD hang fix 92May05 libdd98766.sl: STARBASE HP-UX 8.07 A.08.07 10/09/91 libdd98736.a $Revision: 402.1.1.1 $ PATCH_8.07 genesis_h.o RoboCAD hang fix 92May05 "sum" output: 59522 752 libdd98736.a 37035 888 libdd98736.sl 59522 752 libdd98766.a 37035 888 libdd98766.sl Dependencies: None Supersedes: None Patch Package Size: 1750 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitations of liability and warranties, before installing this patch. Note: Please back up your system before you patch. --------------------------------------------------------------------------- After getting the patch onto your machine, unshar the patch (sh PHSS_1080). To install this patch do the following: 1) Run the update program (Note: you must be logged in as root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/Om" to "Source: /tmp/PHSS_1080.updt" (this assumes that you are in the /tmp directory where PHSS_1080.updt has been placed). Note: You must enter the complete path name. 5) Press "Done". 6) From here on follow standard directions for update. The customize script that update runs will move the original software to /system/PHSS_1080/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHSS_1080.text file to /system/PHSS_1080/ to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example, the following will create a copy of the patch the update can read: dd if=PHSS_1080.updt of=/dev/rmt/Om bs=2048