Patch Name: PHNE_1206 Patch Description: Bad value in the length field of IP option could panic. This happens when the system tries to send back an ICMP error message. Also, the ICMP error message was not correctly built. This was an interrupt type 18, Data memory protection fault on the interrupt stack. The stack trace looks like: panic+0x0028 interrupt+0x07e4 ip_insertoptions+0x01b8 ip_output+0x0080 icmp_send+0x98 icmp_reflect+0x0118 icmp_error+0x0304 ip_dooptions pintr+0x02d4 netisr+0x00a8 Path Name: /hp-ux_patches/s700/8.X/PHNE_1206 Effective Date: 92/06/01 Patch Files: PHNE_1206.updt ip_input.o (/etc/conf/libinet.a) ip_icmp.o (/etc/conf/libinet.a) SR/APR#: none "what" string/timestamp: PATCH_8.05 ip_input.c $Revision: 1.2.185.3 $ PATCH_8.05 ip_icmp.c $Revision: 1.2.185.4 $ "sum" output: 13507 23 ip_input.o 11029 13 ip_icmp.o Dependencies: none Supersedes: none Patch Package Size: 52 Kbytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. After getting the patch onto your machine, unshar the patch (sh PHNE_1206) To install this patch do the following: 1) Run the update program (Note: you must be root to update a system). 2) Once in the update "Main Menu" move the highlighted line to "Change Source or Destination ->" and press "Return" or "Select Item". 3) Make sure the highlighted item in the "Change Source or Destination" window is "From Tape Device to Local System ...", then press "Return" or "Select Item". 4) You should now be in the "From Tape Device to Local System" window. Change the "Source: /dev/rmt/0m" to "Source: PHNE_1206.updt" assuming you are in the directory where PHNE_1206.updt has been placed. In some versions, you may need to enter the absolute path name. In others, the default "/dev/rmt/0m" may not appear in the field as default. 5) Press "Done". 6) Move to the "Select All Filesets on Source Media" line and press "Return". The customized script that update runs will move the original software to /system/PHNE_1206/orig. HP recommends keeping this software there in order to recover from any potential problems. It is also recommended that you move the PHNE_1206.text file to /system/PHNE_1206 to be retained for future reference. If you wish to put this patch on a magnetic tape and update from the tape drive, dd a copy of the patch to the tape drive. As an example the following will create a copy of the patch that update can read: dd if=PHNE_1206.updt of=/dev/rmt/0m bs=2048